连接器电装清洗干燥后隔离电压异常的分析  被引量:1

Analysis of Abnormal Isolation Voltage after Cleaning and Drying of Connector Electrical Assembly

在线阅读下载全文

作  者:孙海浪 王兴刚 杭成 李猛 顾骐 沙亮 潘庆丰 陈乐 余志禄 仇子凡 SUN Hailang;WANG Xinggang;HANG Cheng;LI Meng;GU Qi;SHA Liang;PAN Qingfeng;CHEN Le;YU Zhilu;QIU Zifan(8511 Research Institute of China Aerospace Science and Industry Group,Jiangsu 210007,China)

机构地区:[1]中国航天科工集团八五一一研究所,江苏210007

出  处:《集成电路应用》2021年第8期26-28,共3页Application of IC

摘  要:从连接器电装清洗干燥后隔离电压异常问题入手,对异常批次的电路板加长烘干干燥时间再进行隔离电压的测试数据统计分析,初步确定发生隔离电压异常的原因为连接器烘干时间不够导致绝缘特性变化。进一步试验验证并参阅相关资料,最终确认含有连接器的电路板电装清洗干燥后烘干干燥的时间。并对改善后的效果进行了跟踪验证。Starting with the problem of abnormal isolation voltage after cleaning and drying of connector electrical equipment,the drying time of circuit boards in abnormal batches is extended,and then the test data of isolation voltage are statistically analyzed.It is preliminarily determined that the cause of abnormal isolation voltage is the change of insulation characteristics caused by insufficient drying time of connector.Further test and verify and refer to relevant data to finally confirm the drying time after cleaning and drying the circuit board electrical assembly containing connectors.The improved effect is tracked and verified.

关 键 词:电子器件 连接器 隔离电压 烘干时间 

分 类 号:TN41[电子电信—微电子学与固体电子学] TP212[自动化与计算机技术—检测技术与自动化装置]

 