检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨海涛[1] 冯潇 王振元[1] YANG Haitao;FENG Xiao;WANG Zhenyuan(Department of Thoracic Surgery, the People's Hospital of Liaoning Province, the People's Hospital of China Medical University, Shenyang 110016, China)
机构地区:[1]辽宁省人民医院中国医科大学人民医院胸外科,辽宁沈阳110016
出 处:《中国介入影像与治疗学》2021年第9期513-516,共4页Chinese Journal of Interventional Imaging and Therapy
基 金:辽宁省自然科学基金(2019-ZD-0410)。
摘 要:目的观察CT引导下穿刺活检联合相同针道微波消融治疗肺癌术后同侧单发恶性倾向肺结节的有效性及安全性。方法将56例(56枚结节)肺癌术后同侧单发恶性倾向肺结节患者随机分为观察组和对照组,每组28例。对观察组于CT引导下穿刺活检后经同轴套管同针道行微波消融,对照组于CT引导下穿刺活检后经异穿刺点交叉针道行微波消融,对比2组疗效及并发症。结果2组穿刺活检和微波消融操作成功率、总有效率及局部控制率均为100%。术后24 h内,观察组气胸、咯血及胸腔积液发生率分别为17.86%(5/28)、7.14%(2/28)和7.14%(2/28),对照组分别为21.43%(6/28)、7.14%(2/28)和10.71%(3/28),组间差异均无统计学意义(P均>0.05)。随访6个月,2组均未见针道种植转移、肺栓塞及支气管胸膜瘘等并发症。结论CT引导下穿刺活检联合相同针道微波消融治疗肺癌术后同侧单发恶性倾向肺结节效果确切,安全性较好。Objective To observe the efficacy and safety of CT-guided simultaneous percutaneous core needle biopsy and microwave ablation via coaxial cannula for treatment of solitary pulmonary nodule with malignant tendency occurred on the same side of lung cancer after surgical resection.Methods A total of 56 patients with solitary pulmonary nodule with malignant tendency on the same side of lung cancer after surgical resection were enrolled and randomly divided into study group and control group(each n=28).Patients in study group underwent microwave ablation through the same needle channel after coaxial cannula puncture and biopsy,while those in control group underwent microwave ablation through the cross needle channel at different puncture points after biopsy.The effects and complications were compared between groups.Results The success rate of puncture biopsy and microwave ablation,total effective rate and local control rate were all 100%in 2 groups.Within 24 h after operation,the incidence of pneumothorax,hemoptysis and pleural effusion in study group was 17.86%(5/28),7.14%(2/28)and 7.14%(2/28),respectively,while in control group was 21.43%(6/28),7.14%(2/28)and 10.71%(3/28),respectively.There was no statistical significance between groups(all P>0.05).During 6 months'follow-up,no complication such as needle implant metastasis,pulmonary embolism nor bronchopleural fistula was found in both groups.Conclusion CT-guided simultaneous percutaneous core needle biopsy and microwave ablation via coaxial cannula was effective and safe for treatment of solitary pulmonary nodule with malignant tendency occurred on the same side of lung cancer after surgical resection.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.145.36.157