三种全牙弓扫描策略对仿真头颅模型环境下口内扫描仪扫描精度和时间的影响  被引量:5

Effect of digital intraoral full-arch scan strategies on scan time and accuracy on conditions of intraoral head-simulator

在线阅读下载全文

作  者:武明彤 唐素霞 彭玲燕 陈德平 宿玉成 汪霞 Wu Mingtong;Tang Suxia;Peng Lingyan;Chen Deping;Su Yucheng;Wang Xia(Department of Implantology and Prosthodontics,Beijing Ruicheng Stomatology Hospital,Beijing Ruicheng Implant Technology College,Beijing 100032,China;Department of Stomatology,Peking Union Medical College Hospital,Peking Union Medical College,Chinese Academy of Medical Sciences,Beijing 100033,China)

机构地区:[1]北京瑞城口腔医院种植修复科·种植医学研究院,100032 [2]中国医学科学院,北京协和医学院,北京协和医院口腔种植中心,100033

出  处:《中华口腔医学杂志》2021年第11期1092-1097,共6页Chinese Journal of Stomatology

摘  要:目的对比评价仿真头颅模型环境下口内扫描仪3种全牙弓扫描策略的扫描精度和扫描时间,探讨临床适应性更强且可获得高扫描精度的全牙弓扫描策略。方法采用相互对照实验设计,使用光学扫描仪ATOS Core扫描上颌模型,获取".stl"格式数据作为参考数据。将上颌模型固定于仿真头颅模型上,由1名具有3年口内扫描经验的主治医师使用4种口内扫描仪[A(TRIOS 3)、B(CS 3600)、C(CEREC Omnicam)、D(iTero)],分别使用3种扫描策略(扫描策略1、2、3分别由10、5、7段路径组成)各扫描9次,获取".stl"格式数据作为口扫数据,并记录扫描时间:完成所有扫描路径、获得1个完整的全牙弓数字化模型的时间为全牙弓扫描时间;补扫模型表面图像空缺处的时间为补扫时间;全牙弓扫描时间与补扫时间之和为总扫描时间。使用Geomagic Wrap软件的最佳拟合功能,获得口扫数据与参考数据三维偏差的均方根值,以评价扫描正确度;对同一口内扫描仪同一扫描策略9次扫描获得的口扫数据进行两两比较,获得均方根值以评价扫描精密度。结果使用同一扫描仪的条件下,3种扫描策略扫描正确度的总体差异均无统计学意义(P>0.05);3种扫描策略扫描精密度的总体差异均有统计学意义(P<0.05),其中扫描策略3在各扫描仪中的扫描精密度均为最高。扫描策略1、2、3的全牙弓扫描的时间分别为(130±24)、(72±17)和(90±19)s,各组间差异均有统计学意义(P<0.05)。扫描策略1和3的补扫时间分别为(26±18)和(25±21)s(P>0.05),均显著少于扫描策略2[(50±24)s](P<0.05)。扫描策略2和3的总扫描时间[(122±30)和(115±29)s(P>0.05)]显著少于扫描策略1[(156±31)s](P<0.05)。结论仿真头颅模型环境下使用扫描策略3进行全牙弓扫描,可获得高精度扫描数据,操作更便捷,扫描时间更短,且普适于目前临床常用的口内扫描仪。Objective To comparatively evaluate the accuracy and the scan time of three full-arch scan strategies on the head-simulator,to explore a full-arch scan strategy with better clinical operability and high accuracy.Methods A cross-controlled study design was used.A model with melamine-formaldehyde resin teeth and silica gel gingiva of an upper dental arch which can be fixed on a head simulator was scanned with an optical scanner(ATOS Core)in order to obtain the standard tessellation language(STL)dataset as reference.Intraoral scans were performed on the model fixed on the head simulator with four intraoral scanners(IOS)[A(TRIOS 3),B(CS 3600),C(CEREC Omnicam),D(iTero)].The STL datasets were obtained from each of the four different IOS systems by using three scan strategies(scan strategies 1,2 and 3 were composed of 10,5 and 7 paths respectively)all by one attending doctor with 3 years of intraoral scanning experience.For each scanner and each scan strategy,nine scans were acquired.And the scan time was recorded for each scan.Following the scan strategy,the scan path was completed to obtain a full-arch digital model,and the scan time was recorded as full-arch scan time.Complementary scans were performed to fill the missing image,and this scan time was recorded as complementary scan time.The total scan time was obtained by adding full-arch scan time and complementary scan time.Through the Geomagic Wrap software,the three-dimensional(3D)models were overlaid by best fit alignment function and compared to obtain the root mean square values of the discrepancies by 3D compare function.The intraoral scanning datasets were compared with the reference for trueness.The nine intraoral scanning datasets were cross compared with same scan strategy and same intraoral scanner for precision.Results There were no significant differences among the three scan strategies for trueness(P>0.05),while the differences among the three scan strategies for precision were affected by difference IOSs(P<0.05),and only scan strategy 3 showed the hig

关 键 词:牙科印模技术 牙模型 成像 三维 扫描策略 精度 全牙弓扫描 

分 类 号:R783.6[医药卫生—口腔医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象