城市水厂BAC/UF工艺和臭氧/BAC工艺对比  

Comparison of Biological Activated Carbon/Ultra-Filtration Process and Ozone/Biological Activated Carbon Process in Urban Waterworks

在线阅读下载全文

作  者:邱晓莹 QIU Xiao-ying(China Urban Construction Design&Research Institute,Beijing 100120,China)

机构地区:[1]中国城市建设研究院有限公司,北京100120

出  处:《工程建设与设计》2021年第22期92-94,共3页Construction & Design for Engineering

摘  要:通过对以臭氧/BAC和BAC/UF为深度处理工艺的两水厂进行连续监测,测定TOC、UV254、浊度、颗粒数、细菌总数、生物量、生物分类组成以及微污染物嗅味物质,对2种深度处理工艺进行比较。结果表明:BAC/UF工艺对颗粒物及微生物控制效果明显优于臭氧/BAC工艺;臭氧/BAC工艺对有机物及微污染物的去除效果优于BAC/UF工艺;臭氧/BAC工艺的生物量以及生物多样性高于BAC/UF工艺。Comparing biological activated carbon/ultra-filtration process and ozone/biological activated carbon process by continuous monitoring two waterworks using these two processes to detect the TOC, UV254, turbidity, particle count, total number of bacteria, biomass,biological classification and taste substance of the two waterworks. The result shows that the control effect of BAC/UF process on particulate matter and microbe was better than that of ozone/BAC process;the removal efficiency of organic pollutants and micro pollutants by ozone/BAC process is better than that of BAC/UF;the biomass and biological diversity of ozone/BAC process is higher than that of BAC/UF process.

关 键 词:BAC/UF 臭氧/BAC 颗粒物 有机物 微生物 微污染物 

分 类 号:X143[环境科学与工程—环境科学] TU991.2[建筑科学—市政工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象