原子荧光光谱法测定粮谷中的有机硒和无机硒  被引量:2

Determination of Organic Selenium and Inorganic Selenium in Cereal by Atomic Fluorescence Spectrometry

在线阅读下载全文

作  者:孙文丹 孟强 王景超 于燕萍 田静 于军 商姗姗 张娟 SUN Wendan;MENG Qiang;WANG Jingchao;YU Yanping;TIAN Jing;YU Jun;SHANG Shanshan;ZHANG Juan(Shandong Institute for Product Quality Inspection,Jinan,Shandong 250100,China)

机构地区:[1]山东省产品质量检验研究院,山东济南250100

出  处:《肥料与健康》2021年第6期69-73,共5页Fertilizer & Health

摘  要:建立了原子荧光光谱法测定粮谷中有机硒和无机硒含量的方法。用硝酸消化粮谷,用6 mol/L盐酸溶液控制酸度,测定总硒;以0.1 mol/L盐酸溶液提取粮谷中的无机硒,提取液用环己烷萃取后,收集水相用硝酸-高氯酸消解,用6 mol/L盐酸溶液控制酸度,测定无机硒;总硒与无机硒的差值为有机硒含量。结果表明:硒的质量浓度在30μg/L以内与对应的荧光强度呈线性,无机硒的加标回收率为89.0%~93.8%,其测定值的相对标准偏差小于5%,方法适用于粮谷中无机硒和有机硒的测定。A method for the determination of organic selenium and inorganic selenium in cereal by atomic fluorescence spectrometry is established.The cereal is digested with nitric acid,the acidity is controlled with 6 mol/L hydrochloric acid solution and the total selenium is determined.Inorganic selenium in cereal is extracted with 0.1 mol/L hydrochloric acid solution.After the solution is extracted with cyclohexane,the aqueous phase is collected and digested with nitric acid and perchloric acid.The acidity is controlled with 6 mol/L hydrochloric acid solution to determine inorganic selenium.The difference between total selenium and inorganic selenium is the content of organic selenium.The results show that the mass concentration of selenium under 30μg/L is linear to corresponding fluorescence intensity.The spiked recovery of inorganic selenium is 89.0%-93.8%and the relative standard deviation of the measured value is less than 5%.This method is suitable for the determination of inorganic selenium and organic selenium in cereals.

关 键 词:原子荧光光谱法 有机硒 无机硒 粮谷 

分 类 号:O657.31[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象