雄安站大跨结构风洞试验与风致响应研究  被引量:9

Study on wind tunnel test and wind-induced response of long-span structure for Xiong’an Railway Station

在线阅读下载全文

作  者:张宇 何连华 符龙彪 范重 朱丹 刘涛 李保卫 周鹏飞 ZHANG Yu;HE Lianhua;FU Longbiao;FAN Zhong;ZHU Dan;LIU Tao;LI Baowei;ZHOU Pengfei(China Architecture Design&Research Group,Beijing 100044,China;China Academy of Building Research,Beijing 100013,China;China Construction Third Bureau First Engineering Co.,Ltd.,Wuhan 430040,China)

机构地区:[1]中国建筑设计研究院有限公司,北京100044 [2]中国建筑科学研究院有限公司,北京100013 [3]中建三局第一建设工程有限责任公司,武汉430040

出  处:《建筑结构》2021年第24期13-20,共8页Building Structure

摘  要:雄安站屋盖体型独特,属于风荷载敏感结构,抗风设计非常重要。为明确风荷载取值,对雄安站进行了刚性模型风洞试验。在风洞试验的基础上,着重分析了屋盖悬挑部分风荷载的分布情况。结果表明,屋盖悬挑上表面在剧烈流动分离的影响下风荷载体型系数可达到-2.3;雨棚局部镂空区域对风荷载的影响较小。基于风洞试验得到的风压时程,对屋盖结构进行了风致响应计算,并给出高架候车厅屋盖及雨棚各结构单元不利风向角。最后,采用有限元软件Fluent对过站列车风进行数值模拟分析,得到列车风风压的空间分布形态。列车过站时,结构上的列车风压力峰值随车体与结构距离增大迅速衰减,在列车以350km/h速度运行通过时,高架候车层可满足舒适性要求。The roof of Xiong’an railway station has a unique shape,which is a wind load sensitive structure,so that the wind resistance design is very important.In order to clarify the value of the wind load,the rigid model wind tunnel test was carried out.Based on the wind tunnel test,the wind load distribution of the cantilevered part of the roof was analyzed emphatically.The results show that the wind load shape coefficient of the cantilever upper surface of the roof can reach-2.3 under the influence of violent flow separation.The local hollowed out area of the canopy has little influence on the wind load.Based on the wind pressure time-history obtained from the wind tunnel test,the wind-induced response of the roof structure was calculated,and the adverse wind attack angle of each structural unit of the roof and canopy were given.Furthermore,Fluent software was used to simulate the train induced wind when passing through the station,and the spatial distribution of the train induced wind pressure was obtained.When the train passes the station,the peak value of wind pressure on the structure decreases rapidly with the increase of the distance between the train and the structure.When the train runs through at the speed of 350 km/h,the overhead layer can meet the comfort requirements.

关 键 词:雄安站 大跨屋盖结构 风荷载体型系数 风洞试验 风振分析 列车风 

分 类 号:TU312[建筑科学—结构工程] U292[交通运输工程—交通运输规划与管理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象