基于点分布模型的3D模型拟合方法  被引量:2

3D model fitting method based on point distribution model

在线阅读下载全文

作  者:徐铸业 赵小强[1,2,3] 蒋红梅[1,2,3] XU Zhu-ye;ZHAO Xiao-qiang;JIANG Hong-mei(College of Electrical and Information Engineering,Lanzhou University of Technology,Lanzhou 730050,China;Key Laboratory of Gansu Advanced Control for Industrial Process,Lanzhou University of Technology,Lanzhou 730050,China;National Experimental Teaching Center of Electrical and Control Engineering,Lanzhou University of Technology,Lanzhou 730050,China)

机构地区:[1]兰州理工大学电气工程与信息工程学院,甘肃兰州730050 [2]兰州理工大学甘肃省工业过程先进控制重点实验室,甘肃兰州730050 [3]兰州理工大学国家级电气与控制工程实验教学中心,甘肃兰州730050

出  处:《浙江大学学报(工学版)》2021年第12期2373-2381,共9页Journal of Zhejiang University:Engineering Science

基  金:国家自然科学基金资助项目(61763029,61873116);国防基础科研项目(JCKY2018427C002).

摘  要:针对传统方法构建的患者病患部位的3D解剖结构模型与测试样本拟合效果较差的问题,提出基于点分布模型的3D模型拟合方法(3DMFB-PDM).对训练样本集进行数据处理,使模板样本与目标样本对齐,减小训练样本由于旋转及尺度变化产生的不利影响;在训练样本间建立对应关系,用正态分布表示患者的点分布模型;计算测试样本中的特征点与点分布模型中对应点间的距离,通过引入Mahalanobis距离和转换非线性方程组,使点间距最小.根据最小间距不断调整点分布模型的形状参数,使点分布模型与测试样本拟合.选取30组左侧股骨作为训练样本集实验验证3DMFB-PDM的有效性,结果表明引入附加项后的拟合误差小于未引入附加项的拟合误差.将3DMFB-PDM与其他3种方法进行对比,结果显示3DMFB-PDM的拟合误差最小,表明3DMFB-PDM能够有效地将患者病患部位的3D解剖结构模型与测试样本拟合.A 3D model fitting method based on point distribution model(3DMFB-PDM)was proposed,aiming at the problem of poor fitting between the 3D anatomical structure model of the patient’s part constructed by the traditional method and the test samples.Firstly,the data processing was performed on the training sample set to align the template sample with the target sample,and the adverse effects of training sample due to rotation and scale changes were alleviated.Then the correspondence among training samples was established,and the patient’s point distribution model with a normal distribution was represented.Finally,the distance between the feature point and the corresponding point in the point distribution model was calculated.By introducing the Mahalanobis distance and converting the nonlinear equations were to minimize the distance.Meanwhile,the shape parameters of the point distribution model were continuously adjusted according to the minimum distance,thus the point distribution model was fitted to the test samples.30 groups of left femurs were selected as the training sample set for experimental verification to verify the effectiveness of 3DMFB-PDM.Results show that the fitting error after introducing additional terms is smaller than the fitting error without introducing additional terms.Comparing 3DMFB-PDM with the other three methods shows that the fitting error of 3DMFB-PDM is the smallest,which indicate that 3DMFBPDM can effectively fit the 3D anatomical structure model of the patient’s part to the test samples.

关 键 词:医学图像处理 3D建模 形状分析 点分布模型 MAHALANOBIS距离 

分 类 号:TP391.41[自动化与计算机技术—计算机应用技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象