自动喷水灭火系统局部障碍物下喷头布置探讨  被引量:2

Discussion on sprinkler discharge under obstruction of sprinkler system

在线阅读下载全文

作  者:米长虹 杨培云 孔德骞 MI Changhong;YANG Peiyun;KONG Deqian(The Architectural Design and Research Institute of HIT,Harbin 150090,China;Xiamen Hordor Architecture&Engineering Design Group Co.,Ltd.,Xiamen 361006,China)

机构地区:[1]哈尔滨工业大学建筑设计研究院,哈尔滨150090 [2]厦门合立道工程设计集团股份有限公司,厦门361006

出  处:《给水排水》2022年第1期91-94,117,共5页Water & Wastewater Engineering

摘  要:通过工程实地走访及设计调查,发现自动喷水灭火系统实施中,障碍物下增设喷头布置不满足规范的情况广泛存在。造成这种情况的原因在于自动喷水灭火系统规范相关条文规定的安装距离长度无法满足安装施工要求。通过查阅国内外相关标准与文献、分析与计算,提出可适当增大喷头溅水盘距离障碍物的距离。现有规范使用情况下,提出采用边墙型喷头以减小喷头溅水盘与障碍物的距离。It is found that the arrangement of sprinkler under obstruction does not conform the standard in the implementation of sprinkler system through the project field visit and design investigation. The reason is found that the installation distance stipulated is not satisfied installation requirements in the code for design sprinkler system. It is suggested that the distance between sprinkler deflector and the obstruction can be increased appropriately by referring to relevant literature, analysis and calculation. The side-wall sprinkler is proposed to reduce the distance between the sprinkler deflector and the obstruction during the existing data.

关 键 词:自动喷水灭火系统 障碍物 喷头溅水盘 直立型喷头 下垂型喷头 边墙型喷头 

分 类 号:TU998[建筑科学—市政工程] X799.1[环境科学与工程—环境工程]

 