检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:严东寅[1] 张新庆[1] 唐君伟[1] 谭宇[1] 郑存川[2] Yan Dongyin;Zhang Xinqing;Tang Junwei;Tan Yu;Zheng Cunchuan(PetroChina Tarim Oilfield Company,Tarim,Xinjiang,China;School of Chemistry and Chemical Engineering of Southwest Petroleum University,Chengdu,Sichuan,China)
机构地区:[1]中国石油塔里木油田分公司 [2]西南石油大学化学化工学院
出 处:《石油与天然气化工》2022年第1期20-26,共7页Chemical engineering of oil & gas
摘 要:目的解决天然气脱除酸性气体过程中多数复合吸收溶剂对CO_(2)共吸收率过高、对部分工况条件下Claus硫磺回收单元的运行造成一定影响的问题。方法对比不同杂环胺复合溶剂体系、不同杂环胺质量分数条件下其对天然气中CO_(2)和COS的吸收速率,优选了MDEA与杂环胺的复合体系在塔里木盆地某天然气净化厂进行现场侧线试验。通过考查不同气液比、不同MDEA与杂环胺配比条件下对天然气中酸性组分的吸收效果,并将MDEA、MDEA与1,8-二氮杂双环[5.4.0]十一碳-7-烯(DBU)的复合溶剂(MD)和Sulfinol-M对酸性组分的吸收性能进行对比。结果当MD溶剂中MDEA与DBU复配质量比为5∶5、MD质量分数为40%时,相对于单一MDEA溶液,其COS、CH_(3)SH和CO_(2)脱除率分别提升43.4%、32.3%和5.5%。质量分数为40%的Sulfinol-M对CH_(3)SH和COS的脱除率相比MD分别高7.2%和低10.3%,但对CO_(2)脱除率达到92.2%。结论使用单一的MDEA脱除酸性气体往往难以达到工业要求,而搭配不同杂环胺形成的复合溶剂体系可对酸性气体的吸收起到一定的促进作用。总结了几种不同的复合溶剂体系对酸性气体的吸收情况,可为其他天然气脱除酸性气体工艺提供参考。Objective To solve the problem that most of the composite absorption solvents have too high co-absorption rate of CO_(2) in the process of natural gas deacidification,which will affect the operation of the Claus sulfur recovery unit under certain working conditions.Methods The absorption rate of CO_(2) and COS was compared under the conditions of different heterocyclic amine composite solvent systems and mass fraction.The composite system of MDEA and heterocyclic amine was optimized for field sideline experiments in a natural gas purification plant in Tarim Basin.A method was adopted to examine the absorption effect of acidic components in natural gas under different gas-liquid ratios and different MDEA and heterocyclic amine ratios.The absorption performances of MDEA,MDEA and 1,8-diazabicyclo[5.4.0]undec-7-ene(DBU)composite solvent(MD)and Sulfinol-M for acidic components were compared.Results When the MD solvent compound mass ratio of MDEA to DBU is 5∶5 and the mass fraction of MD was 40%,the removal rate of COS,CH_(3)SH and CO_(2) was increased by 43.4%,32.3%and 5.5%,respectively,compared with a single MDEA solution.The removal rate of CH_(3)SH and COS of Sulfinol-M with a mass fraction of 40%was 7.2%higher and 10.3%lower than that of MD,respectively,but the removal rate of CO_(2) reached 92.2%.Conclusions Using single MDEA to absorb acid gas is often difficult to meet industrial requirements,and a composite solvent system formed with different heterocyclic amines can promote the absorption of acid gas to a certain extent.This article summarized the absorption of acid gas by several different composite solvent systems,which can provide a guidance to other similar process of removing acid gas from natural gas.
分 类 号:TE64[石油与天然气工程—油气加工工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222