检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘莹 赵祥宇[2] 吴刘中[3] 曹灿 LIU Ying;ZHAO Xiangyu;WU Liuzhong;CAO Can(Department of Stomatology,General Hospital of the Northen Theater Command,Shenyang 110016,China;Department of Oral Emergency,Shenyang Stomatological Hospital,Shenyang 110002,China;Department of Periodontics,Shenyang Stomatological Hospital,Shenyang 110002,China)
机构地区:[1]北部战区总医院口腔科,沈阳110016 [2]沈阳市口腔医院综合急诊科,沈阳110002 [3]沈阳市口腔医院牙周科,沈阳110002
出 处:《中国医科大学学报》2022年第2期160-162,168,共4页Journal of China Medical University
基 金:辽宁省自然科学基金(3020-MS-320);沈阳市科技计划(20-205-4-095)。
摘 要:目的探讨超声清洗对钛种植体表面阳极氧化TiO_(2)纳米阵列涂层不同深度氟元素含量的影响。方法配制NH;F、乙二醇溶液作为阳极氧化电解液,以纯钛为阳极,以铂为阴极,在40 V的直流电下形成100 nm管径的TiO_(2)纳米阵列涂层。分为清洗组(NT-W组,制备好的TiO_(2)纳米阵列涂层经过丙酮、乙醇、去离子水顺次清洗10 min)和未清洗组(NT-UW组,不做清洗处理,制备好的TiO_(2)纳米阵列涂层室温下自然干燥)。应用X射线光电子能谱(XPS)检测2组不同深度氟元素的含量分布。沿纳米管长轴方向每500 nm深度刻蚀分析得到NT-W组和NT-UW组的不同深度XPS能谱。截选氟元素重叠峰值数据片段,比较2组氟含量及各组不同深度氟含量。结果XPS结果显示清洗组与未清洗组纳米管管口至管底都有氟元素分布。NT-UW组氟含量显著高于NT-W组(P<0.001)。NT-W组内管口位置氟含量显著低于其他深度(F=25.231,P<0.01)。NT-UW组内不同深度氟含量无统计学差异(F=1.967,P=0.086)。结论超声清洗能明显减少纳米管氟元素含量,但不能彻底清除纳米管内部氟元素。超声清洗针对纳米管表层氟元素去除更为有效。Objective To study the effects of ultrasonic washing method on the fluoride content of anodized TiO_(2) nanotube implant coatings at different depths.Methods NH;F and ethylene glycol solution were prepared as anodizing electrolyte,pure titanium was used as anode,platinum was used as cathode,and a 100 nm diameter TiO_(2) coating was formed under 40 V direct current.By the treatment of ultrasonic washing,the prepared TiO_(2) nanotube arrays were separated into NT-W group and NT-UW group.Every depth of 500 nm across the nanotube were etched.Select the fluoride intensity range.X-ray photoelectron spectroscopy(XPS)were used to analyze the fluoride distribution of nanotubes at different depths.Results The fluoride was distributed from the all length of the nanotubes in the both groups.Compared with NT-UW group,the fluoride of NT-W group was significantly reduced(P<0.001).The fluoride of superficial NT-W group was significantly reduced compared with other depths(F=25.231,P<0.01).There were no differences of different depth of NT-UW group significant(F=1.967,P=0.086).Conclusion The ultrasonic washing method can reduce the fluoride content of nanotubes.After washing treatment more fluoride was remained in the deeper part.The fluoride content of superficial was removed more efficient by ultrasonic washing.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145