检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Amr A.Gab‑Alla
机构地区:[1]Faculty of Medicine,Ophthalmology Department,Suez Canal University,Ring Road,Ismailia,Egypt
出 处:《Eye and Vision》2021年第1期276-285,共10页眼视光学杂志(英文)
摘 要:Background:To evaluate predictability,stability,efficacy,and safety of transepithelial photorefractive keratectomy(TPRK)using smart pulse technology(SPT)(SmartSurface procedure)of Schwind Amaris with mitomycin C for correction of post small incision lenticule extraction(SMILE)myopic residual refractive errors.Method:This study is a prospective,non-comparative case series conducted at a private eye centre in Ismailia,Egypt,on eyes with post-SMILE myopic residual refractive errors because of undercorrection or suction loss(suction loss occurred after the posterior lenticular cut and the creation of side-cuts;redocking was attempted,and the treatment was completed in the same session with the same parameters)with myopia or myopic astigmatism.The patients were followed up post-SMILE for six months before the SmartSurface procedure,and then they were followed up for one year after that.TPRK were performed using Amaris excimer laser at 500 kHz.The main outcomes included refractive predictability,stability,efficacy,safety and any reported complications.Results:This study included 68 eyes of 40 patients out of 1920 total eyes(3.5%)with post-SMILE technique myopic residual refractive errors.The average duration between the SMILE surgery and TPRK was 6.7±0.4 months(range 6 to 8 months).The mean refractive spherical equivalent(SE)was within±0.50 D of plano correction in 100%of the eyes at 12 months post-TPRK.Astigmatism of<0.50 D was achieved in 100%of the eyes.The mean of the residual SE error showed statistically significant improvement from preoperative−1.42±0.52 D to 0.23±0.10 D(P<0.0001).Uncorrected distance visual acuity(UDVA)(measured by Snellen’s chart and averaged in logMAR units)was improved significantly to 0.1±0.07(P<0.0001).UDVA was 0.2 logMAR or better in 100%of the eyes,0.1 logMAR or better in 91.2%of the eyes,and 0.0 logMAR in 20.6%of the eyes.Corrected distance visual acuity(CDVA)remained unchanged in 79.4%of eyes.14.7%of eyes gained one line of CDVA(Snellen).5.9%of eyes gained two lines of CDVA(Sn
关 键 词:Transepithelial PRK Mitomycin C Refractive enhancement Small incision lenticule extraction Smart pulse technology SmartSurface procedure
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.38