人造板甲醛释放量1 m^(3)气候箱法的方法检出限评估  被引量:1

Discussion on Method Detection Limit for 1 m^(3) Climatic Chamber Method to Test Formaldehyde Emission of Wood-based Panels

在线阅读下载全文

作  者:赵卉 孟博 Zhao Hui;Meng Bo(Shenyang Product Quality Supervision Inspection Institute,National Furniture Quality Inspection and Inspection Center(Shenyang),Shenyang 110000,China)

机构地区:[1]沈阳产品质量监督检验院,国家家具质量检验检测中心(沈阳),沈阳110000

出  处:《中国人造板》2022年第4期28-30,共3页China Wood-Based Panels

摘  要:依据GB/T 27417—2017《合格评定化学分析方法确认和验证指南》中空白标准偏差法,对GB/T 17657—2013《人造板及饰面人造板理化性能试验方法》中人造板甲醛释放量1 m^(3)气候箱法的方法检出限进行评估,得到其检出限为0.006 mg/m^(3),为人造板甲醛释放量检验检测提供参考。According to the blank standard deviation method in GB/T 27417—2017 Comformity Assessment-Guidance on Validation and Verification of Chemical Analytical Methods,the mthod detection limit of 1 m^(3) climatic chamber method for formaldehyde emission in GB/T 17657—2013 Testing Methods of Evaluating the Properties of Wood-vbased panels and Surface Decorated Woodbased Panels was studied.The result showed the detection limit was 0.006 mg/m^(3).It could provide a reference for the inspection and detection of formaldehyde emission from wood-based panels.

关 键 词:1 m^(3)气候箱法 甲醛释放量 方法检出限 

分 类 号:TS67[轻工技术与工程]

 