高压设备放电紫外图像光斑区域特征提取  被引量:2

Feature Extraction of Facular Area in Ultraviolet Image of High Voltage Equipment Discharge

在线阅读下载全文

作  者:段文双 闫书佳 单鸿涛[1] 卢金科[3] DUAN Wen-shuang;YAN Shu-jia;SHAN Hong-tao;LU Jin-ke(School of Electronic and Electronical Engineering,Shanghai University of Engineering Science,Shanghai 201620,China;School of Electronic and Information Engineering,Tongji University,Shanghai 201620,China;Liupanshui Electric Power Company,Guizhou Power Grid Co.,Ltd.,Liupanshui,Guizhou 553000,China)

机构地区:[1]上海工程技术大学电子电气工程学院,上海201620 [2]同济大学电子与信息工程学院,上海201620 [3]贵州电网有限责任公司六盘水供电局输电管理所,贵州六盘水553000

出  处:《计算技术与自动化》2022年第1期129-135,共7页Computing Technology and Automation

摘  要:针对传统的高压电气设备紫外漏电检测方法存在的紫外图像处理算法复杂、精确度低等问题,采用基于高斯函数色彩映射的图像分割算法分割进行图像预处理。通过绝缘子污秽放电实验,拍摄高压故障设备紫外辐射图像,对紫外图像进行图像分割处理。从紫外光斑的二值图像中提取故障设备紫外辐射光斑区域特征,评估高压绝缘设备故障等级。实验过程中,在不同的距离拍摄高压放电设备紫外图像,并分析检测距离与紫外辐射区域光斑面积的关系。实验结果表明,高斯函数色彩映射图像分割算法对彩色紫外漏电区域分割效果较好;放电设备紫外光斑区域面积、周长、长轴、短轴四个特征量均可用于表征放电量大小,从而评估高压故障设备故障等级;漏电光斑区域特征量与拍摄距离呈非线性负相关。Aiming at the problems of the traditional high-voltage electrical equipment ultraviolet image detection method,such as the complexity and low accuracy of the ultraviolet image processing algorithm,an image segmentation algorithm based on Gaussian function color mapping is proposed.Through the discharge experiment of pollution insulators,the ultraviolet images was used to shoot the ultraviolet images of the high-voltage faulty equipment,and the ultraviolet images were segmented.Extract the feature of the facular area of the faulty equipment from the binary image of the ultraviolet facular area,and evaluate the fault class of the high-voltage insulation equipment.During the experiment,ultraviolet images of high-voltage discharge equipment were taken at different distances,and the relationship between the detection distance and the facular area was analyzed.The experimental results show that the Gaussian function color mapping image segmentation algorithm has a better effect on the segmentation of the color facular area;the four characteristic of the discharge equipment ultraviolet spot area,perimeter,long axis,and short axis can be used to characterize the size of the discharge,so as to evaluate the fault class of the high-voltage fault equipment;the characteristic quantity of the leakage facular area has a non-linear negative correlation with the shooting distance.

关 键 词:故障检测 绝缘子污秽放电 图像分割 高斯函数 特征提取 

分 类 号:TP391.41[自动化与计算机技术—计算机应用技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象