检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Veronica Vargas Jorge L.Alio Rafael I.Barraquer Justin Christopher D'Antin Cristina Garcia Francisco Duch Joan Balgos Jorge L.Alio del Barrio
机构地区:[1]Vissum Instituto Oftalmologico de Alicante,Alicante,Spain [2]Division of Ophthalmology,Universidad Miguel Hernandez,Alicante,Spain [3]lnstitut Universitari Barraquer,Universitat Autonoma de Barcelona,Barcelona,Spain [4]Centro de Oftalmologia Barraquer,Barcelona,Spain [5]Universitat Internacional de Catalunya,Barcelona,Spain [6]Clinica Real Vision,Madrid,Spain [7]Instituto Catalan de Retina(ICR)unidad de Cirugáa Refractiva,Barcelona,Spain
出 处:《Eye and Vision》2022年第1期33-40,共8页眼视光学杂志(英文)
摘 要:Background:To evaluate the safety,efficacy,refractive outcomes and causes for bilensectomy[phakic intraocular lens(plOL)explantation with cataract surgery and pseudophakic intraocular lens(IOL)implantation]in patients previously implanted with posterior chamber plOLs(PC plOLs).Methods:This multi-center retrospective study included 87 eyes of 55 patients who underwent bilensectomy for PC plOL with a follow-up time of 12 months.The uncorrected and corrected distance visual acuities(UDVA,CDVA),endothelial cell density before and after bilensectomy were assessed,as well as the cause of bilensectomy and intra or postoperative complications.Results:There was a statistically significant improvement in UDVA and CDVA after bilensectomy(P=0.00).The main reason for bilensectomy was cataract development(93.1%of the cases),followed by miscalculation of lens size,and corneal edema.The endothelial cell count remained stable without a statistically significant change after surgery(P=0.67).The refractive efficacy index was 0.8,none of the patients lost lines of CDVA after surgery,73%of the patients were within±1.0D(spherical equivalent)of the target refraction.Intraoperative complications were one posterior capsule rupture with the IOL implanted in the sulcus,and three eyes required the use of pupil expanders for adequate pupil dilation.Postoperatively,one eye developed retinal detachment.The three plOLs models explanted were the implantable collamer lens(ICL);implantable phakic contact lens(IPCL)and the phakic refractive lens(PRL).Conclusions:Good safety and visual outcomes were observed one year after bilensectomy for PC plOLs.There were few intra and postoperative complications and there was no significant endothelial cell loss after the bilensectomy procedure.
关 键 词:Bilensectomy Posterior chamber phakic intraocular lenses CATARACT Endothelial cell count Visual outcomes Postoperative complications Intraoperative complications
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117

