Association between axial length and toric intraocular lens rotation according to an online toric back-calculator  被引量:2

在线阅读下载全文

作  者:Jennifer L.Patnaik Malik Y.Kahook John P.Berdahl David R.Hardten Brandie D.Wagner Leonard K.Seibold Brent A.Kramer 

机构地区:[1]Department of Ophthalmology,University of Colorado School of Medicine,Aurora,Colorado 80045,USA [2]Vance Thompson Vision,Sioux Falls,South Dakota 57108,USA [3]Minnesota Eye Consultants,Minneapolis,Minnesota 55404,USA [4]Department of Biostatistics,Colorado School of Public Health,Aurora,Colorado 80045,USA [5]Department of Ophthalmology,University of North Carolina,Chapel Hill,North Carolina 27517,USA

出  处:《International Journal of Ophthalmology(English edition)》2022年第3期420-425,共6页国际眼科杂志(英文版)

基  金:OSD, Inc.;Alcon;New World Medical;Johnson and Johnson Vision。

摘  要:AIM: To assess the relationship between axial length(AL) and intraocular lens(IOL) rotation among eyes receiving a toric IOL and subsequently entered into an online toric back-calculator database.METHODS: Retrospective analysis of data collected online via astigmatismfix.com, a freely available online toric back-calculator where surgeons enter pre-and postoperative information to help manage residual postoperative astigmatism.Included records were deemed valid with entry of AL and IOL orientation between January 2017 and March 2019.Rotation was determined by a difference of ≥5° between pre-operative intended IOL orientation and actual post-operative IOL orientation.Frequency and magnitude of rotation are presented with means and associated standard deviation(SD).Linear regression models of this association are presented.RESULTS: Records of 6752 eyes were included in the analysis, of which 74.8% were determined to have a rotated IOL.The magnitude of rotation increased with each millimeter(mm) increase in AL with a mean rotation of 13.3°(SD: 12.8°) for eyes with AL 20-20.9 mm and a maximum mean rotation of 30.6°(SD: 30.3°) among eyes with AL 29-29.9 mm.General linear modeling demonstrated a significant association(P<0.0001) with a parameter estimate of 1.19(standard error: 0.159) and R;of 0.0083.CONCLUSION: Analysis from an online database indicates that toric IOLs inserted into eyes with longer AL are more likely to rotate and to rotate more degrees from the target axis.The findings from this study are clinically relevant for surgeons implanting toric IOLs.

关 键 词:cataract surgery toric lens axial length ROTATION 

分 类 号:R779.66[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象