检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Tenia Wang Alex S.Baldwin Robert F.Hess
机构地区:[1]Faculty of Science,McGill University,Montreal,QC,Canada [2]Department of Ophthalmology,Montreal General Hospital,McGill University,Montreal,QC,Canada
出 处:《Annals of Eye Science》2019年第1期194-194,共1页眼科学年鉴(英文)
摘 要:Background:The human visual system extracts depth information from disparity in the images seen by the two eyes.The ability to calculate depth from disparity will be disrupted if local retinal abnormalities distort parts of those images,especially if these distortions are different in the two eyes.In its early stages,age-related macular degeneration(AMD)causes slight distortions in the central vision field which differ in the two eyes.AMD is the most common form of irreversible blindness in people over the age of 50.The goal of this project is to develop a stereoscopic perception test which leverages the sensitivity of binocular depth perception to detect the interocular differences symptomatic of either early-stage AMD or other diseases affecting the retina.Methods:A program was written in MATLAB that allowed separate left and right eye stimuli to be shown to the two eyes.NVIDIA 3D Vision 2 stereoscopic glasses were used to present the stimuli.The test we have developed consists of random dot patterns covering the central 5 degrees of vision.One or more disk-shaped perturbations in depth are displayed at different locations in the visual field of the subjects.Of the ten possible target locations,we present between one and four disks on each trial.The disks will only be visible if there is an undistorted input for that visual field location from the two retinae.The participant uses a keypad to report the number of floating disks seen.A set of trials with randomized locations and numbers of disks is used to gather initial data on likely areas of stereoscopic vision deficit;afterwards,likelihoods for deficits in each location are calculated and used to generate customized subsequent trials.Results:The software to perform the local stereovision test has been developed and is now being piloted.We are currently collecting data from healthy normal subjects prior to applying the test to clinical populations.In order to simulate the central vision distortions of AMD,patches of the stimulus for one eye are scrambled and b
关 键 词:Age-related macular degeneration(AMD) STEREOVISION binocular disparity stereoscopic perception
分 类 号:TP3[自动化与计算机技术—计算机科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7