作 者:冯庭勇 钟晶亮 文贤馗 杨大慧 邓彤天 FENG Tingyong;ZHONG Jingliang;WEN Xiankui;YANG Dahui;DENG Tongtian(The Electrical Engineering College,Guizhou University,Guiyang 550025,China;Electric Power Research Institute of Guizhou Power Grid Co.,Ltd.,Guiyang 550002,China;Postgraduate Workstation of Guizhou Power Grid Co.,Ltd.,Guiyang 550002,China)
机构地区:[1]贵州大学电气工程学院,贵州贵阳550025 [2]贵州电网有限责任公司电力科学研究院,贵州贵阳550002 [3]贵州电网有限责任公司研究生工作站,贵州贵阳550002
出 处:《热力发电》2022年第5期136-141,共6页Thermal Power Generation
基 金:贵州省科技厅科技支撑计划资助项目(黔科合支撑[2020]2Y064);国家重点研发计划项目(2017YFB0903600)。
摘 要:为实现先进绝热压缩空气储能(AA-CAES)系统在宽负荷段参与AGC调频,且调节速率不超过《广东调频辅助服务市场交易规则》规定(避免产生考核电量),提出一种多级分段设置PID控制器参数参与机组自动发电控制(AGC)调频的控制策略。通过APROS仿真平台分别对10 MW AA-CAES机组采用单套与3套PID控制器响应AGC控制指令进行仿真。结果表明:AA-CAES发电系统机组采用1套PID控制器在宽负荷段响应AGC控制指令,调频性能指标K1大于5,给储能电站增加考核电量而造成经济损失;机组采用3套不同参数PID控制器能够优化调频性能指标,使调频性能指标K1在要求范围内,从而避免产生考核电量,有效提高AA-CAES发电系统参与辅助调频服务的经济效益。In order to realize the advanced adiabatic compressed air energy storage(AA-CAES) system participates in AGC frequency regulation in wide load range, and ensure the regulation rate does not exceed the Guangdong Frequency Regulation Auxiliary Service Market Transaction Rules(to avoid generating checking energy), a control strategy with multi-level segmented parameter setting PID controller participating in the frequency regulation of unit automatic generation control(AGC) is proposed. Through APROS simulation platform, the response of 10 MW AA-CAES unit to AGC control instructions is simulated by using a single set of PID controllers and three sets of PID controllers. The research results show that, when the AA-CAES power generation system unit adopts one set of PID controller to respond to the AGC control instructions in wide load section range, the frequency modulation performance index K1 is greater than 5, which increases the assessment power of the energy storage power station and causes economic losses. When the unit adopts three sets of PID controllers with different parameters to optimize the frequency modulation performance index, the frequency modulation performance index K1 is within the required range, thereby the possibility of generating electricity for assessment is avoided and the economic benefits of the AA-CAES power generation system participating in auxiliary frequency modulation service is effectively improved.
关 键 词:先进绝热压缩空气储能 调频辅助服务 PID控制器 AGC性能考核
分 类 号:TM92[电气工程—电力电子与电力传动]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.170