机构地区:[1]南京医科大学附属眼科医院,南京210029 [2]温州医科大学附属眼视光医院,温州325027
出 处:《中华眼视光学与视觉科学杂志》2022年第2期131-136,共6页Chinese Journal Of Optometry Ophthalmology And Visual Science
摘 要:目的:评估Pentacam眼前节分析系统测量的眼前节生物学参数在巩膜镜(SL)验配初始镜片矢高(LSD)选择中的应用价值。方法:回顾性系列病例研究。选取2020年10月至2021年6月于南京医科大学附属眼科医院验配SL的角膜不规则散光或干眼患者32例(53眼)。所有患者均行SL验配前一般眼科检查,采用Pentacam采集角膜前表面平坦曲率(Kf)、陡峭曲率(Ks)、散光量、非球面参数Q值、中央角膜厚度(CCT)、角膜直径、前房深度(ACD)等数据。此外,采用Pentacam自带软件测量受检眼于13.50 mm弦长下的角膜矢高(CSH)。采用Pearson或Spearman相关以及线性回归分析各眼前节生物学参数与最终试戴评估修正后LSD的关系。结果:患者均完成初次SL试戴验配。Pentacam眼前节分析系统Scheimpflug images模式下所测量的13.50 mm弦长下CSH为(3746±187)μm,试戴修正后LSD为(3622±206)μm。相关分析结果显示:角膜前表面Kf、Ks、散光量、ACD及Pentacam测量的CSH与试戴修正后的LSD均呈正相关(r=0.36~0.84,均P<0.05);CCT与试戴修正后LSD呈负相关(r=-0.35,P=0.011);非球面参数Q值、角膜直径与试戴修正后LSD无相关性。将试戴修正后LSD作为因变量,校正相关因素后的线性回归方程显示Pentacam测量的CSH与试戴修正后LSD高度相关,即试戴修正后LSD=416.996+0.854×CSH(调整R2=0.63,F=89.17,P<0.001)。结论:Pentacam测量的部分眼前节生物学参数与SL试戴修正后的LSD相关,其中CSH可作为LSD选择的重要参考依据。Objective:To evaluate the value of using the Pentacam anterior segment analyzer to measure ocular anterior segment parameters in the selection of initial lens sagittal depth(LSD)for scleral lenses(SL).Methods:Retrospective serial case study.Thirty-two patients(53 eyes)with irregular corneal astigmatism or dry eye disease were enrolled and fitted with SL in the Affiliated Eye Hospital of Nanjing Medical University from October 2020 to June 2021.All patients underwent general ophthalmic examinations before the initial SL fitting evaluation.Pentacam was used to obtain the ocular anterior segment parameters,such as flat keratometry(Kf),steep keratometry(Ks),corneal astigmatism,aspheric factor(Q-value),central corneal thickness(CCT),corneal diameter,and anterior chamber depth(ACD).In addition,the built-in caliper of the Pentacam was used to measure corneal sagittal height(CSH)at a 13.50 mm chord length.A Pearson or Spearman correlation analysis was used to evaluate the relationship between the modified LSD and above-mentioned parameters measured by Pentacam,and a linear regression model was created.Results:All patients completed the first SL fitting evaluation.The CSH measured in the Scheimpflug images of the Pentacam were 3746±187μm under a 13.50 mm chord length,and the modified LSD was 3622±206μm after fitting.The results of a correlation analysis showed that the modified LSD was positively associated with Kf,Ks,corneal astigmatism,ACD and CSH(r ranged from 0.36 to 0.84,all P<0.05).The modified LSD was negatively correlated with CCT(r=-0.35,P=0.011).However,there was no correlation between the Q-value or corneal diameter and the modified LSD.Defining the modified LSD as a dependent variable,the linear regression model showed that CSH measured by Pentacam was highly correlated with the modified LSD after correcting for the other covariates.The linear regression equation is LSD=416.996+0.854×CSH(adjusted R2=0.63,F=89.17,P<0.001).Conclusions:Some ocular anterior segment parameters measured by Pentacamare correlate
关 键 词:巩膜镜 Pentacam眼前节分析系统 角膜矢高 镜片矢高
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...