Medium-term clinical efficacy and safety of single incision and modified trans-obturator mid-urethral slings for female stress urinary incontinence  

在线阅读下载全文

作  者:Jerome Melon Paivi K.Karjalainen Claire McGannon Joseph K.Lee Anna Rosamilia 

机构地区:[1]Pelvic Floor Unit,Monash Medical Centre,Melbourne,VIC,Australia [2]Central Finland Central Hospital,Jyvaskyla,Finland [3]Department of Obstetrics and Gynaecology,Monash Medical Centre,Melbourne,VIC,Australia [4]University of New South Wales,Kensington,NSW,Australia [5]Cabrini Hospital Malvern,Melbourne,VIC,Australia

出  处:《Gynecology and Obstetrics Clinical Medicine》2022年第2期57-62,共6页妇产科临床医学(英文)

摘  要:Aims:To evaluate the medium term efficacy and safety of Altis and Solyx single incision slings(SIS)compared with tension-free vaginal tape(TVT)Abbrevo trans-obturator sling.We hypothesize that both SIS show little difference in efficacy and safety and perform similarly to TVT Abbrevo.Methods:We conducted an ambispective comparative cohort study of women with stress urinary incontinence who received a SIS in comparison to matched TVT Abbrevo subjects from a concurrent randomized controlled trial(RCT).Subjects were identified retrospectively,and prospectively invited for examination and questionnaires>12 months post-operatively.Exclusions included intrinsic sphincter deficiency,previous sling surgery,and others.Primary outcome was subjective cure[negative response to International Consultation Incontinence Questionnaire-Urinary Incontinence Short Form(ICIQ-UI SF)question 6,leakage during coughing/activity].Secondary outcomes include objective cure(negative cough stress test),functional outcomes,and adverse events.Results:Between 2012 and 2018,a total of 113 women received one of two SIS surgeries;Solyx(n=50)followed by the Altis(n=63);104 were available for final efficacy analysis.Mean follow-up was 21.7(Altis),46.0(Solyx),and 29.0(Abbrevo)months.Baseline characteristics were comparable between the groups.There was no significant differences in the subjective or objective cure rates between the groups,and no differences in functional outcomes such as patient global impression of improvement,and post-operative ICIQ-UI SF score.There was a low rate of mesh related complications and no differences seen between the groups.Conclusions:Despite being an underpowered study,Altis and Solyx SIS have favourable efficacy and safety profiles which are comparable to an established trans-obturator mid-urethral slings(MUS).

关 键 词:EFFICACY Mini-sling SAFETY Single incision sling Stress urinary incontinence 

分 类 号:R69[医药卫生—泌尿科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象