检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Jing Zhang Yi-Bo Huo Jia-Liang Yang Xiang-Zhou Wang Bo-Yun Yan Xiao-Hui Du Ru-Qian Hao Fang Yang Juan-Xiu Liu Lin Liu Yong Liu Hou-Bin Zhang
机构地区:[1]MOEMIL Laboratory,School of Optoelectronic Information,University of Electronic Science and Technology of China,Chengdu,Sichuan 610054,China [2]Key Laboratory for Human Disease Gene Study of Sichuan Province,Sichuan Provincial People’s Hospital,University of Electronic Science and Technology of China,Chengdu,Sichuan 610072,China
出 处:《Zoological Research》2022年第5期738-749,共12页动物学研究(英文)
基 金:supported by the National Natural Science Foundation of China (61405028 to J.Z.,81770935 to H.B.Z.);Fundamental Research Funds for the Central Universities (University of Electronic Science and Technology of China)(ZYGX2019J053 to J.Z.);Department of Science and Technology of Sichuan Province,China (2020YJ0445 to H.B.Z.)。
摘 要:Glaucoma is characterized by the progressive loss of retinal ganglion cells (RGCs),although the pathogenic mechanism remains largely unknown.To study the mechanism and assess RGC degradation,mouse models are often used to simulate human glaucoma and specific markers are used to label and quantify RGCs.However,manually counting RGCs is time-consuming and prone to distortion due to subjective bias.Furthermore,semi-automated counting methods can produce significant differences due to different parameters,thereby failing objective evaluation.Here,to improve counting accuracy and efficiency,we developed an automated algorithm based on the improved YOLOv5 model,which uses five channels instead of one,with a squeeze-and-excitation block added.The complete number of RGCs in an intact mouse retina was obtained by dividing the retina into small overlapping areas and counting,and then merging the divided areas using a non-maximum suppression algorithm.The automated quantification results showed very strong correlation (mean Pearson correlation coefficient of 0.993) with manual counting.Importantly,the model achieved an average precision of 0.981.Furthermore,the graphics processing unit (GPU) calculation time for each retina was less than 1 min.The developed software has been uploaded online as a free and convenient tool for studies using mouse models of glaucoma,which should help elucidate disease pathogenesis and potential therapeutics.
关 键 词:Retinal ganglion cell Cell counting Glaucomatous optic neuropathies Deep learning Improved YOLOv5
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.38