检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王景荣[1] 岳璞[1] 任春燕[1] 赵娟[1] 张瑜 何可维 WANG Jing-rong;YUE Pu;REN Chun-yan;ZHAO Juan;ZHANG Yu;HE Ke-wei(Xi’an Modern Chemistry Research Institute,Xi’an 710065,China)
出 处:《应用化工》2020年第S02期317-319,共3页Applied Chemical Industry
摘 要:以某改性单基发射药为研究对象,采用聚焦微波消解法,将试样消解为试样溶液,以火焰原子吸收法测定其中的钾元素含量,结果表明,钾元素的平均回收率为104.3%(n=7),相对标准偏差(RSD)为3.47%(n=7),其测定结果与传统电热板消解法无显著性差异,消解时间缩短1 h。A new method for respective determination of K in modified single base propellant sample was proposed by flame atomic absorption spectrometry with focused microwave assisted digestion.The results of determining K in the modified single base propellant,show that the RSD(relative standard deviations)is 3.47%(n=7)and the average recovery is 104.3%.The result of atomic absorption spectrometry with the focused microwave assisted digestion method shows no significant difference with that of the traditional digestion by electic heating plate,the digestion time decrease 1 hour as well.