计算机数控铣削技术对不同牙预备体的钛金属冠三维适合性的影响  被引量:2

Effects of computer numerical control milling technology on the three-dimensional fit of titanium crowns with different tooth preparation designs

在线阅读下载全文

作  者:喻娜[1,2,3] 陈剑 谭发兵 周后祺[5] 王鹏 YU Na;CHEN Jian;TAN Fabing;ZHOU Houqi;WANG Peng(Department of Dental Technology,Stomatological Hospital of Chongqing Medical University,Chongqing 400015,China;Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences,Chongqing 400015,China;Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education,Chongqing 400015,China;Department of Medical Device Production Examination,Center of Chongqing Pharmaceutical Technology Evaluation and Certification,Chongqing 401120,China;Chongqing Jingmei Denture Manufacturing Company Limited,Chongqing 400015,China)

机构地区:[1]重庆医科大学附属口腔医院修复工艺科,重庆400015 [2]口腔疾病与生物医学重庆市重点实验室,重庆400015 [3]重庆市高校市级口腔生物医学工程重点实验室,重庆400015 [4]重庆市药品技术审评认证中心医疗器械生产审查科,重庆401120 [5]重庆晶美义齿制作有限公司,重庆400015

出  处:《中国医科大学学报》2022年第10期870-875,共6页Journal of China Medical University

基  金:重庆市科技局技术创新与应用发展专项(cstc2020jscx-sbqwX0006);重庆市教育委员会科学技术研究计划(KJQN202100439)。

摘  要:目的评估计算机数控(CNC)铣削技术中计算机辅助设计(CAD)和铣削步骤对不同牙预备体的钛金属冠三维适合性的影响。方法应用Imageware软件构建5种形态的牙预备体数据,应用牙科软件分别设计得到牙冠数据,然后将各牙冠数据铣削得到钛金属冠。喷砂后,采用E4模型扫描获取牙冠凹面数据,采用Studio软件最佳拟合配准获得颜色偏差图和均方根误差(RMSE),最后对CAD和铣削步骤后的RMSE进行统计分析。结果经CAD步骤后,5个设计组颜色偏差图不完全相同,RMSE均值范围为27.99~31.01μm;经CAD和铣削步骤后,各设计组颜色偏差图发生明显变化,RMSE均值范围为22.62~55.20μm;铣削步骤本身的RMSE均值范围为-6.26~24.19μm,且90°翘边组RMSE均值为(24.19±7.48)μm,较其他设计组更大(P<0.05)。与CAD步骤相比,铣削步骤牙冠的RMSE均值更小(P<0.05)。结论CAD或铣削步骤均易对钛金属冠三维适合性产生影响,且影响程度因预备体形态而存在差异,但这种差异与临床可接受的适合性偏差相比较小。Objective To evaluate the effects of computer aided design(CAD)and milling procedures in computer numerical control(CNC)milling technology on the three-dimensional fit of titanium crowns with different tooth preparation designs.Methods Five preparation data were constructed using Imageware software,after which design crowns were obtained,and then the crown data were milled to obtain titanium actual crowns.After sandblasting,E4 model scanning was used to obtain the intaglio surfaces data of the actual crowns,and after obtaining the best-fit algorithm using the Studio software,the three-dimensional fit was displayed with colors,while the root mean square error(RMSE)was calculated and analyzed.Results After the CAD procedure,the color-coded images of the five design groups were not identical,and the mean RMSE ranged from 27.99 to 31.01μm.After the CAD and milling procedures,the color-coded images of each design group changed obviously,and the mean RMSE ranged from 22.62 to 55.20μm.The mean RMSE of the milling procedure itself ranged from-6.26 to 24.19μm,and the mean RMSE of the 90°with lipped margins group was higher than that of the other design groups(P<0.05).In addition,compared with the CAD procedure,the mean RMSE of crowns in the milling procedure was smaller(P<0.05).Conclusion CAD or milling procedures are prone to affect the three-dimensional fit of titanium crown,and the degree of influence varies with the design of the tooth preparation.However,comparing to clinically acceptable fit discrepancies,the differences are relatively small.

关 键 词:计算机辅助设计 铣削 牙预备体设计 钛金属冠 三维适合性 

分 类 号:R783.2[医药卫生—口腔医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象