Refractive outcomes and optical quality of PRESBYOND laser-blended vision for presbyopia correction  被引量:4

在线阅读下载全文

作  者:Dan Fu Aruma Aruma Ye Xu Tian Han Fei Xia Xing-Tao Zhou 

机构地区:[1]Eye Institute and Department of Ophthalmology,Eye&ENT Hospital,Fudan University,Shanghai 200030,China [2]NHC Key Laboratory of Myopia(Fudan University),Key Laboratory of Myopia,Chinese Academy of Medical Sciences,Shanghai 200031,China [3]Shanghai Research Center of Ophthalmology and Optometry,Shanghai 200031,China [4]Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care,Shanghai 200031,China

出  处:《International Journal of Ophthalmology(English edition)》2022年第10期1671-1675,共5页国际眼科杂志(英文版)

基  金:Supported by National Natural Science Foundation of China(No.81770955);National Natural Science Foundation of China for Young Scholars(No.82000929);Project of Shanghai Science and Technology(No.20410710100);Clinical Research Plan of SHDC(No.SHDC2020CR1043B);Project of Shanghai Xuhui District Science and Technology(No.2020-015);Project of Shanghai Xuhui District Science and Technology(No.XHLHGG202104);Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care(No.20DZ2255000);Shanghai Sailing Program(No.20YF1405000);。

摘  要:AIM: To investigate the one-year refractive outcomes and optical quality following PRESBYOND laser-blended vision(LBV).METHODS: This retrospective study included 20 patients who underwent PRESBYOND treatment between Jan 2019 and Aug 2020. The patients were asked to attend a followup outpatient visit one year after surgery. Distance and near visual acuity as well as subjective refraction were examined. Optical quality was assessed using wavefront-supported custom ablation. A questionnaire evaluating optical quality and satisfaction was completed at the last visit.RESULTS: The average patient age was 48.1±7.4 y(range, 41 to 58 y). The mean preoperative spherical equivalent was-7.59±2.39D. At the one-year follow-up, two eyes(both dominant eyes) lost one line of corrected distance visual acuity(CDVA), while the remaining eyes(38/40) maintained or gained lines of CDVA. The average binocular uncorrected distance visual acuity improved from 0.15±0.03 to 0.90±0.26(decimal vision;P<0.001). The average binocular uncorrected near visual acuity increased from 0.34±0.28 to 0.97±0.07(P<0.001). The spherical aberration was 0.04±0.06 μm in the nondominant eye and 0.09±0.09 μm in the dominant eye(P=0.02). All patients were satisfied with or accepted the outcomes of the surgery. The primary complaints were related to disturbances in night vision and relatively inferior near vision.CONCLUSION: Over the one-year observation period, PRESBYOND is a safe and effective option for presbyopia correction. The optical quality and near vision deserve further investigation.

关 键 词:PRESBYOND laser-blended vision PRESBYOPIA optical quality 

分 类 号:R778.14[医药卫生—眼科]

 