检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王聪[1] 董雪瑞 谢磊[1] 张利果 高莹 张浩杰 王宇翔 WANG Cong;DONG Xuerui;XIE Lei;ZHANG Liguo;GAO Ying;ZHANG Haojie;WANG Yuxiang(Ecology and Health Institute,Hangzhou Vocational&Technical College,Hangzhou 310018,China)
机构地区:[1]杭州职业技术学院生态健康学院,杭州310018
出 处:《理化检验(化学分册)》2022年第9期1017-1021,共5页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基 金:浙江省自然科学基金(LY19B050002);杭职院科研课题项目(ky202112)。
摘 要:采用多孔聚偏氟乙烯膜包裹多壁碳纳米管制备成多孔膜保护固相微萃取装置,该装置经水洗涤、甲醇活化、干燥后,放入1 L样品中,包膜以500 r·min^(-1)的速率搅拌30 min,吸附富集痕量苯系物。取出包膜,在1 mL甲醇中解吸5 min后获得浓缩的苯系物样品,经气相色谱-质谱法分析,比对NIST 14谱库并结合标准品的气相色谱保留时间对其中的10种痕量苯系物进行定性,采用外标法定量。结果表明,应用自制的固相微萃取装置,可有效去除体系的基质干扰,提高萃取效率,与NIST 14谱库比对定性,富集的10种苯系物的匹配度均不小于90%,说明方法定性准确。定量分析时,10种苯系物的质量浓度在1.000~1 000 ng·L^(-1)内与对应的峰面积呈线性关系,检出限为0.010~0.013 ng·L^(-1)。按照标准加入法进行回收试验,回收率为97.5%~100%,测定值的相对标准偏差(n=5)为0.89%~1.5%。方法用于测定12份实际水样,其中1份样品中氯苯检出量为179.0 ng·L^(-1),1份样品中对二甲苯检出量为151.0 ng·L^(-1)。Porous polyvinylidene fluoride membrane was used to wrap multi-walled carbon nanotubes(MWCNTs) to prepare a solid phase micro-extraction device. After water washing, methanol activating and drying, the device was put into 1 L of the sample, and the coating was stirred at a rate of 500 r·min^(-1)for 30 min to adsorb and enrich trace benzene series. The coating was taken out and desorbed for 5 min in 1 mL of methanol to get the benzene series sample concentrated, in which 10 trace benzene series were analyzed by gas chromatography-mass spectrometry. 10 trace benzene series were identified by compared with NIST 14 spectrum library and the gas chromatographic retention time of the standards, and quantified by external standard method. As shown by the results, the application of self-made solid phase micro-extraction device could effectively remove the matrix interference of the system and improve extraction efficiency. Compared with NIST 14 spectrum library, the matching degree of 10 enriched benzene series was not less than 90%, indicating that qualitative analysis for this method was accurate. In quantitative analysis, linear relationships between values of peak area and mass concentration of 10 benzene series were found in the range of 1.000-1 000 ng·L^(-1), with detection limits in the range of 0.010-0.013 ng·L^(-1). Test for recovery was made by standard addition method, giving results in the range of 97.5%-100%, with RSDs(n=5) of the determined values ranged from 0.89% to 1.5%. This method was applied to determination of 12 actual water samples, among which the detection amount of chlorobenzene in one sample was 179.0 ng·L^(-1)and that of paraxylene in the other sample was 151.0 ng·L^(-1).
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30