作 者:董向阳 陈世强 唐文哲 陈方兴 樊思雨 朱祝龙 陈洋 DONG Xiangyang;CHEN Shiqiang;TANG Wenzhe;CHEN Fangxing;FAN Siyu;ZHU Zhulong;CHEN Yang(School of Resource&Environment and Safety Engineering,Hunan University of Science and Technology,Xiangtan Hunan 411201,China;School of Civil Engineering,Hunan University of Science and Technology,Xiangtan Hunan 411201,China;Tunnel Design Branch,China Railway Liuyuan Group Co.,Ltd.,Tianjin 300133,China)
机构地区:[1]湖南科技大学资源环境与安全工程学院,湖南湘潭411201 [2]湖南科技大学土木工程学院,湖南湘潭411201 [3]中铁第六勘察设计院集团有限公司隧道设计分公司,天津300133
出 处:《中国安全生产科学技术》2022年第11期148-154,共7页Journal of Safety Science and Technology
基 金:国家自然科学基金项目(51864014);湖南省自然科学基金项目(2021JJ60053);湖南省研究生科研创新项目(QL20210235)。
摘 要:针对现有行业规范中的排烟口结构参数尚不明确的问题,依托过海瓦贵区间隧道,搭建隧道通风排烟模型实验系统。设定11种排烟口面积工况,结合实验与数值模拟,得到排烟口上、下游的静压值和风速。引入动能修正系数,推导出基于上下游能量差的排烟口局部阻力表达式,绘制出无量纲面积比与局部阻力系数曲线族。研究结果表明:排烟口长宽比值较大时,不利于排烟口下方风流流动;在同一风机组合工况下,当排烟口面积缩小时,局部阻力系数会呈现出先减后增的趋势;提出排烟口最优结构长宽比为1.06。研究结果可为相关规范制定提供参考,并为防灾救灾提供理论支持。In view of the unclear structural parameters of smoke vent in the existing industry specifications,a model experimental system of tunnel ventilation and smoke exhaust was built relying on the sub-sea Wagui running tunnel.11 sets of operating conditions of the exhaust vent area were set,and the static pressure and wind velocity at the upstream and downstream of exhaust vent were obtained combining with experiments and numerical simulation.The kinetic energy correction coefficient was introduced,then the expression for local resistance of the smoke vent based on the energy difference between upstream and downstream was deduced,and the curve family of the dimensionless area ratio and the local resistance coefficient was drawn.The results showed that when the length-width ratio of the exhaust vent was large,it was not conducive to the airflow flowing under the smoke vent.Under the same combined conditions of fan,when the area of smoke vent was reduced,the local resistance coefficient presented a trend of decreasing first and then increasing.The optimal structural length-width ratio of smoke vent was 1.06.The results can provide reference for the formulation of relative specifications and theoretical support for the disaster prevention and rescue.
分 类 号:X962[环境科学与工程—安全科学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7