作 者:张海龙 李博 贾娜娟 ZHANG Hailong;LI Bo;JIA Najuan(State Grid Gansu Electric Power Company Pingliang Power Supply Company,Pingliang 744000,China)
机构地区:[1]国网甘肃省电力公司平凉供电公司,甘肃平凉744000
出 处:《电信科学》2023年第1期92-99,共8页Telecommunications Science
摘 要:智能运维设备发生脱网故障后,往往难以定位,为实现脱网故障区段与故障电流分布间映射关系的确定、寻找脱网故障区段与故障电流分布间映射关系的最短路径,设计一种基于Dijkstra算法的电力光通信网络智能运维设备脱网故障区段定位方法。选择数据驱动方法中的LightGBM算法,通过大量样本确定离网故障区段与故障电流分布之间的映射关系。基于Dijkstra算法寻找映射关系的最短路径,实施脱网故障区段搜索。设计电力光通信网络智能运维设备脱网故障区段定位平台,实现脱网故障点即智能运维设备信号丢失的定位与告警。对比实验显示,在SDH环网电路区域中的光缆中断导致的脱网故障区段定位、多路由段的光缆故障下的脱网故障区段定位,以及在环状电力区域中的多路由段的光缆故障下的脱网故障区段定位场景中,该方法的定位结果与实际位置最贴近,定位最准确。In order to determine the mapping relationship between the off grid fault section and the fault current distribution, and find the shortest path between the off grid fault section and the fault current distribution, an off grid fault section location method based on Dijkstra algorithm was designed for the intelligent O&M equipment of the electro-optical communication network. The LightGBM algorithm in the data-driven method was selected to determine the mapping relationship between the off grid fault section and the fault current distribution through a large number of samples. Based on Dijkstra algorithm, the shortest path of mapping relationship was found, and the off network fault section was searched. The location platform for off grid fault section of intelligent operation and maintenance equipment of power optical communication network was designed to realize the location and alarm of off grid fault point, namely, signal loss of intelligent operation and maintenance equipment. The comparison experiment shows that the location result of this method was the closest to the actual location and the most accurate in the off network fault section location caused by the interruption of optical cable in the SDH ring network circuit area, the off network fault section location caused by the fault of optical cable in the multi way bus section, and the off network fault section location scenario caused by the fault of optical cable in the multi way bus section in the ring power area.It effectively improved the accuracy of fault location and has good applicability.
关 键 词:DIJKSTRA算法 电力光通信网络 数据驱动方法 智能运维设备 IBFA算法 脱网故障区段定位
分 类 号:TM77[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.216.1.197