作  者:王猛 李欣[1] 卫赵斌 郭雅兴 WANG Meng;LI Xin;WEI Zhaobin;GUO Yaxing(Beijing Construction Engineering Group Co.,Ltd.,Beijing 100055,China;Hebei Key Laboratory of Civil Engineering Catastrophe Control and Disaster Emergency Response,Langfang 065201,China;Architectural Engineering College,North China Institute of Science and Technology,Langfang 065201,China)

机构地区:[1]北京建工集团有限责任公司,北京100055 [2]河北省土木工程灾变控制与灾害应急重点实验室,廊坊065201 [3]华北科技学院建筑工程学院,廊坊065201

出  处:《建筑结构》2023年第6期40-46,共7页Building Structure

摘  要:准确把握建筑楼盖结构的动力特性是结构设计和健康监测研究的重要工作。在介绍基于运行模态分析法的结构模态参数识别方法的基础上,以北京工人体育场项目为例,采用有节奏运动人群激励对体育场直线T型板和弧线T型板进行了振动检测,采用脉动法对体育场看台混凝土结构进行了振动检测,获得了看台板及看台结构的振动加速度数据,并利用频域识别方法进行了模态参数识别。结果表明:体育场直线T型板、弧线T型板固有频率分别分布在5.94、11.88Hz附近,分别属于中、高频板。体育场看台结构悬挑端固有频率主要分布在4.3~9.38Hz之间,看台结构设计满足《建筑楼盖结构振动舒适度技术标准》(JGJ/T 441—2019)要求。体育场高区南北向栈桥区域看台悬挑端固有频率较低,建议现场应避免长期使用频率为4.3、2.15Hz附近的音乐。It is important to accurately obtain the dynamic characteristics of building floor structure in structural design and health monitoring study.On the basis of introduction of structural modal parameter identification method based on operational modal analysis,the Beijing Workers Stadium project was taken as an example,the rhythmic motion crowd excitation was used for vibration test of the stadium linear T-slab and arc T-slab,and the pulsation method was used for vibration test of the concrete structure of the stadium stand,and the vibration acceleration data of the stand slab and the stand structure were obtained,and the modal parameters were identified by using the frequency domain identification method.The results show that the natural frequencies of the stadium linear T-slab and arc T-slab are distributed around 5.94 and 11.88Hz respectively,which are medium and high frequency slab.The natural frequency of the overhanging end of the stadium stand structure is mainly distributed between 4.3~9.38Hz,and the design of the stand structure meets the requirements of the Technical standard of vibration comfort of the floor structure(JGJ/T 441-2019).Stadium high area north-south trestle bridge area stand overhanging end natural frequency is low,it is recommended that the site should avoid the long term use of music near the frequency of 4.3 and 2.15Hz.

关 键 词:北京工人体育场 看台混凝土结构 动力特性 动力响应 固有频率 

分 类 号:TU375[建筑科学—结构工程] X839[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象