基于SHOT与目标函数对称ICP的低重叠率术前术中点云配准算法  被引量:1

Low overlap rate preoperative and intraoperative point cloud registration algorithm based on SHOT and symmetric objective function ICP

在线阅读下载全文

作  者:严文磬 张立静 王玮[3] 武博[1,2] YAN Wenqing;ZHANG Lijing;WANG Wei;WU Bo(School of Biomedical Engineering,Capital Medical University,Beijing 100069;Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application,Capital Medical University,Beijing 100069;Xuanwu Hospital,Capital Medical University,Beijing 100053)

机构地区:[1]首都医科大学生物医学工程学院,北京100069 [2]首都医科大学临床生物力学应用基础研究北京市重点实验室,北京100069 [3]首都医科大学宣武医院,北京100053

出  处:《北京生物医学工程》2023年第2期111-116,共6页Beijing Biomedical Engineering

摘  要:目的配准是术前影像引导的椎弓根螺钉内固定术中的重要环节。术前CT影像三维重建获得的点云和术中捕获的暴露部位点云重叠率低,易受噪声、遮挡等因素的干扰,使点云配准更具挑战性。本文采用局部特征和距离度量相结合的方式应对低重叠率配准问题。方法首先利用方向直方图描述子(signature of histograms of orientations,SHOT)和随机抽样一致算法(random sample consensus,RANSAC)提取并匹配几何特征相似的点,完成初始对齐。应用目标函数对称ICP,通过最小化对称化点到面目标函数得到最终变换矩阵。对来源于SpineWeb公开数据集的5组腰椎数据进行配准实验。结果术前术中点云配准实验中平均配准误差为0.128 mm,平均运行时间为5.750 s。结论实验结果验证了该算法在低重叠率术前术中点云配准中的有效性,使得外科医生能及时根据配准结果调整手术器械,从而提高椎弓根螺钉置入准确率。Objective Registration is an important part of preoperative image-guided pedicle screw fixation.The point cloud obtained by the 3D reconstruction of the preoperative CT image and the point cloud of the exposed part captured during the operation have a low overlap rate and are easily interfered by factors such as noise and occlusion,which makes the point cloud registration more challenging.This paper adopts the combination of local geometric features and distance measurement to deal with the problem of low overlap registration.Methods Firstly,the points with similar geometric features were extracted and matched using the signature of histograms of orientations descriptor(SHOT)and the random sample consensus(RANSAC)to complete the initial alignment.Applying the objective function symmetric ICP algorithm,the final transformation matrix was obtained by minimizing the symmetric point-to-surface objective function.Registration experiments were performed on five groups of lumbar spine data from the SpineWeb public dataset.Results In the preoperative and intraoperative point cloud registration experiments,the average registration error was 0.128 mm,and the average running time was 5.750 s.Conclusions The experimental results verify the effectiveness of the algorithm in the preoperative and intraoperative point cloud registration with low overlap rate,which enables surgeons to adjust the surgical instruments according to the registration results in time,thus improving the accuracy of pedicle screw placement.

关 键 词:点云配准 方向直方图描述子 目标函数对称ICP 低重叠率 跨源配准 

分 类 号:R318.04[医药卫生—生物医学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象