长期持续配戴软性角膜接触镜对近视患者角膜透明度的影响  被引量:3

Effect of long-term wear of soft contact lenses on corneal transparency in myopes

在线阅读下载全文

作  者:董亚慧 侯杰 张静 许亚菲 雷玉琳 Dong Yahui;Hou Jie;Zhang Jing;Xu Yafei;Lei Yulin(Jinan Mingshui Eye Hospital,Jinan 250200,China)

机构地区:[1]济南明水眼科医院,济南250200

出  处:《中华实验眼科杂志》2023年第4期344-350,共7页Chinese Journal Of Experimental Ophthalmology

基  金:济南市卫生健康委员会科技计划项目(2022-2-191)。

摘  要:目的探讨长期持续配戴软性角膜接触镜对角膜透明度的影响。方法采用横断面研究方法,对2018年1月至2020年12月在济南明水眼科医院拟行角膜屈光手术的女性近视患者行角膜光密度检查,按照患者持续配戴角膜接触镜的时间将患者分为配戴≥2年~<5年组、配戴≥5年~<10年组和配戴≥10年组,同期纳入年龄、性别匹配和未配戴角膜接触镜者作为对照组,每组50例50眼。以角膜中心为圆心将受检眼角膜划分为直径范围0~2、2~6、6~10、10~12 mm 4个环区,并按照角膜层次将角膜分为浅层(距角膜前表面≤120μm)、深层(距角膜后表面≤60μm)和中间层(角膜浅、深层之间),均取右眼测量结果纳入研究,比较各组受检眼不同角膜环区各层的角膜光密度值。结果随着角膜接触镜配戴时间的延长,角膜光密度值呈下降趋势。对照组、配戴≥2年~<5年组、配戴≥5年~<10年组和配戴≥10年组受检眼角膜光密度值分别为18.51±1.79、18.25±2.10、18.16±1.89和17.83±1.65,总体比较差异无统计学意义(F=1.152,P=0.329)。各组角膜0~2、2~6和6~10 mm环区浅层光密度值总体比较,差异均无统计学意义(F=2.077、2.080、2.229,均P>0.05)。10~12 mm环区浅层角膜光密度值总体比较,差异有统计学意义(F=5.016,P=0.002),其中配戴≥5年~<10年组浅层角膜光密度值高于对照组和配戴≥2年~<5年组,配戴≥10年组角膜光密度值高于对照组,差异均有统计学意义(均P<0.05)。各组角膜0~2 mm和6~10 mm环区中间层光密度值总体比较,差异均有统计学意义(F=3.808、2.813,均P<0.05),其中配戴≥10年组角膜光密度值低于对照组,差异有统计学意义(P<0.05)。各组角膜0~2、2~6、6~10和10~12 mm环区深层光密度值总体比较,差异均有统计学意义(F=5.485、5.625、3.398、2.775,均P<0.05),其中配戴≥5年~<10年组角膜0~2、2~6和10~12 mm深层角膜光密度值明显低于对照组和配戴≥2年~<5年组,配戴≥5�Objective To investigate the influence of long-term wear of soft contact lenses on corneal transparency.Methods A cross-sectional study was conducted.The corneal optical density of female myopic patients who planned to undergo corneal refractive surgery in Jinan Mingshui Eye Hospital from January 2018 to December 2020 was examined.The patients were divided into≥2-<5 years group,≥5-<10 years group,and≥10 years group according to the duration of wearing contact lenses.Age-and sex-matched patients without wearing soft contact lenses were enrolled as a control group.There were 50 eyes from 50 cases in each group.The cornea was divided into 0-2,2-6,6-10,and 10-12 mm corneal vertex-centered annuli.The cornea over each annulus was divided into a superficial layer(≤120μm from the outer surface of the cornea),a deep layer(≤60μm from the inner surface of the cornea)and a central layer(between the superficial and deep layers).Measurements of the right eye were taken for analysis.The corneal optical density of different layers over different corneal ring regions was compared.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Jinan Mingshui Eye Hospital(No.2018-005).Written informed consent was obtained from each subject before any medical examination.Results The corneal optical density tended to decrease as the wearing duration of corneal contact lens extended.The corneal optical density values of control group,≥2-<5 years group,≥5-<10 years group,and≥10 years group were 18.51±1.79,18.25±2.10,18.16±1.89 and 17.83±1.65,respectively,showing no significant difference(F=1.152,P=0.329).There was no significant difference in the corneal optical density of the superficial layer over 0-2,2-6,and 6-10 mm annuli among the four groups(F=2.077,2.080,2.229;all at P>0.05).There was a significant difference in the corneal optical density of the superficial layer over 10-12 mm annulus among the four groups(F=5.016,P=0.002),and the corneal optical density of the

关 键 词:近视 软性接触镜 角膜 光密度测定法 透明度 

分 类 号:R778.11[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象