检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:毛梦芸 王成泽 朱海华[1] 樊明星 吴笑妃 朱赴东[1] MAO Meng-yun;WANG Cheng-ze;ZHU Hai-hua;FAN Ming-xing;WU Xiao-fei;ZHU Fu-dong(Stomatology Hospital,School of Stomatology,Zhejiang University School of Medicine,Clinical Research Center for Oral Diseases of Zhejiang Province,Key Laboratory of Oral Biomedical Research of Zhejiang Province,Cancer Center of Zhejiang University,Hangzhou 310006,China;Hangzhou 6D Dental Tech Co,Ltd,Hangzhou 310000,China;Department of Stomatology,the Fifth People’s Hospital of Yuhang District,Hangzhou 311100,China)
机构地区:[1]浙江大学医学院附属口腔医院,浙江大学口腔医学院,浙江省口腔疾病临床医学研究中心,浙江省口腔生物医学研究重点实验室,浙江大学癌症研究院,杭州310006 [2]杭州六维6D牙科科技有限公司,杭州310000 [3]杭州市余杭区第五人民医院口腔科,杭州311100
出 处:《解剖学报》2023年第2期244-248,共5页Acta Anatomica Sinica
基 金:中国牙病防治基金重点项目(A2021-008);浙江大学医学院附属口腔医院探索与研发项目(RD2022DLYB07)。
摘 要:目的设计一款辅助颌骨内异物取出术的新型手术导板,并进行体外模型评估和临床验证。方法基于锥形束计算机断层扫描数据和环钻技术,自主设计颌骨内异物取出术的外科手术导板,通过体外羊下颌骨模型评估该导板的可行性和准确性,并将其成功应用于临床病例。通过在柱状骨的六角和顶点处测量7个参数(cdh、cda、hdh、hda、vdh、vda和ad)距离,计算轴偏移角,评估实际去除和计划去除圆柱状骨之间的线性和角度偏差。结果体外模型显示该导板的六角和顶点的平均中心偏差分别为(0.51±0.14)mm和(0.62±0.19)mm。六角处的水平偏差为(0.48±0.16)mm,顶点处的水平偏差为(0.52±0.22)mm,六角处的垂直偏差为(0.17±0.09)mm,顶点处的垂直偏差为(0.29±0.13)mm,角度偏差为(5.38±3.43)°;在临床病例中,术者在导板帮助下,成功定位并取出了颌骨内断裂的根管锉。结论本款新型手术导板能够有效辅助目标性定位和微创性取出颌骨内断裂器械等异物。Objective To design and validate a novel surgical guide for retrieval of foreign body in jaw.Methods Firstly,a surgical guide based on cone beam computed tomography and trephine technique was designed to remove broken dental instrument fragments.Its feasibility and accuracy were assessed by removing broken dental instrument in goat mandible,and then it was successfully applied in clinical cases.The linear and angular discrepancies between actual and planned columnar bone with imaginary fragment was analyzed.The euclidean distance was measured at the hex and apex of the columnar bone and the angle of axis deviation was also calculated.We obtained seven parameters(cdh,cda,hdh,hda,vdh,vda,and ad)to describe deviations.Results Mean central deviation at the hex and apex was(0.51±0.14)mm and(0.62±0.19)mm,respectively.Accompanying mean values were as follow:horizontal deviation at the hex was(0.48±0.16)mm,horizontal deviation at the apex was(0.52±0.22)mm,vertical deviation at the hex was(0.17±0.09)mm,vertical deviation at the apex was(0.29±0.13)mm,and angular deviation of(5.38±3.43)degrees.In a clinical case,the guide successfully located and removed the fracture file.Conclusion This study reveals that this kind novel surgical guide could aid to locate and remove the foreign body in jaw.
关 键 词:手术导板 下颌骨异物 锥形束计算机断层扫描 羊
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.218.65.88