检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张子淼[1] 张昊 许凯 张福民[2] ZHANG Zimiao;ZHANG Hao;XU Kai;ZHANG Fumin(School of Mechanical Engineering,Tianjin University of Technology and Education,Tianjin 300222,China;State Key Laboratory of Precision Measuring Technology and Instruments,Tianjin University,Tianjin 300072,China)
机构地区:[1]天津职业技术师范大学机械工程学院,天津300222 [2]天津大学精密测试技术及仪器国家重点实验室,天津大学,天津300072
出 处:《传感技术学报》2023年第3期389-396,共8页Chinese Journal of Sensors and Actuators
基 金:国家自然科学基金项目(51905378);天津市教委科研计划重点项目(2022ZD029)。
摘 要:摄像机内参数标定直接影响位姿测量精度。在自然光条件下采集图像,由于光照不均匀,使靶标图像产生局部高亮现象,降低了标定点图像坐标提取精度。针对这一问题,提出一种基于光偏振信息的摄像机标定方法,分两步完成摄像机标定,第1步,使用自然光条件下采集的图像完成摄像机标定;第2步,在镜头前加装偏振片,根据第1步得到的标定结果,针对不同偏振角条件下采集得到的图像,计算靶标平面与摄像机像平面之间的2D单应矩阵进而根据相应的重投影误差确定当靶标摆放在不同位置时所对应的最佳偏振角,最终使用该偏振角条件下采集的图像,完成摄像机标定。实验结果表明,该方法可以有效提升摄像机标定精度,进而提升位姿测量精度:在-45°~+45°范围内,平均测量误差低于0.019°,与使用自然光条件下标定参数的位姿测量相比,测量精度提升了0.01°。在0~20 mm范围内,平均测量误差低于0.03 mm,与使用自然光条件下标定参数的位姿测量相比,测量精度提升了0.043 mm。The calibration of camera parameters direct affects the accuracy of pose measurement.When the image is collected under natural light conditions,due to the uneven illumination,the target image has a local highlight phenomenon,which reduces the extraction accuracy of the image coordinates of calibration points.To solve this problem,a camera calibration method is proposed based on light polarization information.The camera calibration is completed in two steps.Step 1,the images collected under natural light conditions are used to complete the camera calibration;Step 2,a polarizer is added in front of the lens,according to the calibration results obtained in the first step.For the images collected under the condition of different polarization angles,the 2D homography matrix between the target plane and the camera image plane is calculated,and then the optimal polarization angle is determined when the target is placed in different positions according to the corresponding re-projection error,and finally the images collected under the condition of polarization angles are used to complete the camera calibration.The experimental results show that the proposed method can effectively improve the camera calibration accuracy,and then improve the pose measurement accuracy.In the range of-45°-+45°,the average measurement error is less than 0.019°,and the measurement accuracy is improved by 0.01°compared with pose measurement using the calibration parameters under natural light conditions.In the range of 0-20 mm,the average measurement error is less than 0.03 mm,and the measurement accuracy is improved by 0.043 mm compared with pose measurement using the calibration parameters under natural light conditions.
分 类 号:TP391[自动化与计算机技术—计算机应用技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7