检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王欧兰 贾晓妍 刘杰 孙孟 刘可玉 吴继魁[1] WANG Oulan;JIA Xiaoyan;LIU Jie;SUN Meng;LIU Keyu;WU Jikui(Shanghai Engineering Research Center of Aquatic-Product Processing&Preservation,College of Food Science and Technology,Shanghai Ocean University,Shanghai 201306,China)
机构地区:[1]上海市水产品加工与保鲜工程技术研究中心,上海海洋大学食品学院,上海201306
出 处:《分析试验室》2023年第4期545-550,共6页Chinese Journal of Analysis Laboratory
摘 要:构建了一种简单快速的“非空腔式”细菌表面印迹(SPBIP)阻抗传感器,用于对沙门氏菌进行超灵敏检测。SPBIP传感器由吡咯(功能单体)、单壁碳米管(SWNT,纳米调控剂)和沙门氏菌(模板)一步电聚合到玻碳电极上,去除细菌模板后,在聚合物基质表面形成“非空腔式”的印迹位点,使目标细菌可特异性的重新结合,由此产生的电极表面阻抗变化可用于检测目标细菌。研究了SWNT用量、聚合圈数、洗脱剂、洗脱时间和识别时间等对传感器识别能力的影响。在最佳条件下,该传感器可用于检测10~1×10^(7)CFU/mL沙门氏菌且检出限为3.5 CFU/mL。该传感器可用于饮用水和橙汁样品检测,回收率在95.4%~109.5%之间。A simple and fast"non-hole"bacteria surface imprinted(SPBIP)impedance sensor was constructed for ultrasensitive detection of Salmonella.The SPBIP sensor was prepared by one step electropolymerization of pyrrole(functional monomer),single-walled carbon nanotube(SWNT,nano-modulator),and Salmonella(template)onto a glassy carbon electrode.After removing the bacterial template,"non-hole"imprinted sites were formed on the surface of the polymer matrix,allowing the target bacteria to be specifically recognized.The resulting changes in the electrode surface impedance could be used to detect the target bacteria.The effects of the amount of SWNT,polymerization cycles,eluents,elution time and recognition time on the recognition ability of the sensor were investigated.Under the optimal conditions,the sensor could be used to detect 10~1×107 CFU/mL Salmonella with the limit of detection of 3.5 CFU/mL.The sensor could be used for the detection of salmonella in drinking water and orange juice samples with the recoveries ranging from 95.4%to 109.5%.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.218.92.96