作 者:江艳婷 刘勇 高洁[2] 董长鸿 蒋晓东 JIANG Yanting;LIU Yong;GAO Jie;DONG Changhong;JIANG Xiaodong(Department of Radiotherapy,Affiliated Lianyungang Hospital of Xuzhou Medical University,Lianyungang 222000,China;Lianyungang Clinical College of Nanjing Medical University,Lianyungang222000,China)
机构地区:[1]徐州医科大学附属连云港医院放疗科,江苏连云港222000 [2]南京医科大学连云港临床医学院,江苏连云港222000
出 处:《中华肿瘤防治杂志》2023年第11期680-686,共7页Chinese Journal of Cancer Prevention and Treatment
摘 要:目的探讨乳腺癌改良根治术后使用3D打印不均匀厚度补偿物、3D打印均匀厚度补偿物及普通补偿物所做放疗计划的差异。方法选取就诊于徐州医科大学附属连云港医院的15例乳腺癌改良根治术后患者,分别使用3种不同补偿物放疗,比较3组计划的靶区和危及器官的剂量学及体积学参数差异。结果3组计划中,3D打印不均匀补偿物均匀性指数(HI)为0.10±0.03,3D打印均匀补偿物为0.11±0.04,普通补偿物为0.15±0.05,F=13.819,P<0.001;适形性指数(CI)分别为0.75±0.07、0.75±0.07和0.68±0.08,F=25.674,P<0.001;3D打印补偿物最大间隙深度为(0.44±0.16)cm,小于普通补偿物的(1.55±0.39)cm,t=-9.113,P<0.001。但2种3D打印补偿物之间差异无统计学意义,P>0.05。结论3D打印补偿物个性化程度高,在患者的贴合度、靶区剂量的均匀性、适形性方面具有优势,在乳腺癌改良根治术后放疗中有较大临床应用价值。Objective To explore the difference of radiotherapy plans made by using 3Dprinted non-uniform thickness compensation,3Dprinted uniform thickness compensation and general compensation after modified radical mastectomy for breast cancer.Methods Totally fifteen patients with breast cancer after modified radical mastectomy who were treated in Affiliated Lianyungang Hospital of Xuzhou Medical University were selected,and three different compensators were used for radiotherapy respectively.The differences in dosimetry and volumetric parameters between the planned target areas and the endangered organs of the three groups were compared.Results In the three groups of plans,the homogeneity index(HI)value of uneven compensation for 3Dprinting was 0.10±0.03,the uniform compensation for 3Dprinting was 0.11±0.04,and the ordinary compensation was 0.15±0.05,F=13.819,P<0.001.The conformity index(CI)values were 0.75±0.07,0.75±0.07,and 0.68±0.08,respectively,F=25.674,P<0.001.The maximum gap depth of 3Dprinting compensation was(0.44±0.16)cm,which was lower than(1.55±0.39)cm of ordinary compensation,t=-9.113,P<0.001.However,there was no statistically significant difference between the two 3Dprinting compensators(P>0.05).Conclusion The 3Dprinting compensators are highly personalized,and have advantages in patient fit,target dose uniformity,and conformability.They have great clinical application value in post modified radical surgery radiotherapy for breast cancer.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.170