检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Fatemeh Mosayebi Seyyed Mehdi Tabatabaee Haleh Kangari Saeed Rahmani
机构地区:[1]Department of Optometry,School of Rehabilitation,Shahid Beheshti University of Medical Sciences,Tehran 19839-63113,Iran [2]Department of Biostatistics,School of Rehabilitation,Shahid Beheshti University of Medical Sciences,Tehran 19839-63113,Iran
出 处:《International Journal of Ophthalmology(English edition)》2023年第8期1287-1292,共6页国际眼科杂志(英文版)
摘 要:AIM:To determine the effects of change in light conditions on refractive error and visual functions including visual acuity,stereopsis and contrast sensitivity.METHODS:This cross-sectional study was conducted in the optometry clinic of the Shahid Beheshti School of Rehabilitation on 48 students in 2021-2022.All of them had eye health and normal visual function and could have refractive errors or not.Light intensity of 4 lx was considered equivalent to photopic light condition and light intensity of 1 lx was considered to be equivalent to mesopic light condition.The amount of refractive error was checked by auto refractometer and its changes in mesopic light condition were subjectively measured.Also,visual acuity,stereopsis and contrast sensitivity(in five spatial frequencies of 1.5,3,6,12,and 18 cycles per degree),were measured first in photopic light condition and then in mesopic light condition,by Snellen control vision chart,stereo butterfly test and the M&S technology monitor test respectively.RESULTS:In the 48 student subjects with an average age of 22.69±3.56y,mean of refractive error as sphere equivalent,visual acuity and stereopsis were-1.25±1.74 diopters,0 logMAR,44.37±13.03 seconds of arc,respectively in photopic light condition while in mesopic light was equal to-1.56±1.75 diopters,0.12±0.09 logMAR and 50.62±33.35 seconds of arc,respectively.The mean of contrast sensitivity measured at spatial frequencies of 1.5,3,6,12,and 18 cycles per degree in photopic condition was equal to 2.38±0.04,2.37±0.07,2.04±0.21,1.27±0.32,0.82±0.27 logarithm of contrast sensitivity,respectively and in mesopic lighting condition was equal to 2.34±0.12,2.30±0.16,1.84±0.28,1.02±0.28,0.63±0.24 logarithm of contrast sensitivity,respectively.Statistical analysis showed a significant difference between the two lighting conditions in all evaluated variables[refractive error(P<0.001),visual acuity(P<0.001),stereopsis(P=0.008)and contrast sensitivity(P<0.001)].CONCLUSION:The refractive error of the student subjects in
关 键 词:mesopic light condition photopic light condition visual performance visual acuity STEREOPSIS contrast sensitivity visual functions
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222