Comprehensive Treatment Uncertainty Analysis and PTV Margin Estimation for Fiducial Tracking in Robotic Liver Stereotactic Body Radiation Therapy  被引量:1

在线阅读下载全文

作  者:Zhi-wen LIANG Meng-lan ZHAI Biao TU Xin NIE Xiao-hui ZHU Jun-ping CHENG Guo-quan LI Dan-dan YU Tao ZHANG Sheng ZHANG 

机构地区:[1]Cancer Center,Union Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430022,China

出  处:《Current Medical Science》2023年第3期572-578,共7页当代医学科学(英文)

基  金:This project was supported by the National Key R&D Program of China(No.2016YFC105300).

摘  要:Objective This study aims to quantify the uncertainties of CyberKnife Synchrony fiducial tracking for liver stereotactic body radiation therapy(SBRT)cases,and evaluate the required planning target volume(PTV)margins.Methods A total of 11 liver tumor patients with a total of 57 fractions,who underwent SBRT with synchronous fiducial tracking,were enrolled for the present study.The correlation/prediction model error,geometric error,and beam targeting error were quantified to determine the patient-level and fraction-level individual composite treatment uncertainties.The composite uncertainties and multiple margin recipes were compared for scenarios with and without rotation correction during treatment.Results The correlation model error-related uncertainty was 4.3±1.8,1.4±0.5 and 1.8±0.7 mm in the superior-inferior(SI),left-right,and anterior-posterior directions,respectively.These were the primary contributors among all uncertainty sources.The geometric error significantly increased for treatments without rotation correction.The fraction-level composite uncertainties had a long tail distribution.Furthermore,the generally used 5-mm isotropic margin covered all uncertainties in the left-right and anterior-posterior directions,and only 75%of uncertainties in the SI direction.In order to cover 90%of uncertainties in the SI direction,an 8-mm margin would be needed.For scenarios without rotation correction,additional safety margins should be added,especially in the superior-inferior and anterior-posterior directions.Conclusion The present study revealed that the correlation model error contributes to most of the uncertainties in the results.Most patients/fractions can be covered by a 5-mm margin.Patients with large treatment uncertainties might need a patient-specific margin.

关 键 词:CYBERKNIFE fiducial tracking liver cancer stereotactic body radiation therapy margin expansion 

分 类 号:R730.55[医药卫生—肿瘤]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象