同步调相机同期并网成功率的计算方法  

Analysis of Calculation Method for the Success Rate of Synchronous Grid Connection of Synchronous Condenser

在线阅读下载全文

作  者:杨志贤 刘阳 董杰 湛志成 桂华 YANG Zhixian;LIU Yang;DONG Jie;ZHAN Zhicheng;GUI Hua(Sifang Jibao(Wuhan)Software Co.,Ltd.,Hubei 430223,China)

机构地区:[1]四方继保(武汉)软件有限公司,湖北430223

出  处:《集成电路应用》2023年第7期270-273,共4页Application of IC

摘  要:阐述惰速过程中频差和角差的变化规律,提出频差合格窗口和同期窗口的概念,给出并网成功与失败的确切定义。在此基础上,探讨并网成功率的具体计算方法,包括并网成功判据、并网失败判据,介于二者之间的判据,给出并网成功率计算公式,并对典型工程的并网成功率给出了计算算例。This paper describes the variation law of frequency difference and angle difference during the coasting process, proposes the concepts of qualified frequency difference window and synchronous window, and provides the exact definition of successful and failed grid connection. On this basis, specific calculation methods for the success rate of grid connection are explored, including grid connection success criteria, grid connection failure criteria, and criteria between the two. The calculation formula for the success rate of grid connection is given, and calculation examples are given for the success rate of grid connection of typical projects.

关 键 词:额定转速 频差定值 角差定值 并网成功率 