作 者:叶盛佳 杨晓燕 章家铭 忻贤贞[1] 魏斌[2] 曾丽[1] 宫耀 YE Sheng-jia;YANG Xiao-yan;ZHANG Jia-ming;XIN Xian-zhen;WEI Bin;ZENG Li;GONG Yao(Department of Prosthodontics,Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine,College of Stomatology,Shanghai Jiao Tong University,National Center for Stomatology,National Clinical Research Center for Oral Diseases,Shanghai Key Laboratory of Stomatology,Shanghai Research Institute of Stomatology.Shanghai 200011,China;Special Dental Consultation Clinic,Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine,College of Stomatology,Shanghai Jiao Tong University,National Center for Stomatology,National Clinical Research Center for Oral Diseases,Shanghai Key Laboratory of Stomatology,Shanghai Research Institute of Stomatology.Shanghai 200011,China;Department of Orthodontics,Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine,College of Stomatology,Shanghai Jiao Tong University,National Center for Stomatology,National Clinical Research Center for Oral Diseases,Shanghai Key Laboratory of Stomatology,Shanghai Research Institute of Stomatology.Shanghai 200011,China)
机构地区:[1]上海交通大学医学院附属第九人民医院口腔修复科,上海200011 [2]口腔第一门诊,上海交通大学口腔医学院,国家口腔医学中心,国家口腔疾病临床医学研究中心,上海市口腔医学重点实验室,上海市口腔医学研究所,上海200011 [3]口腔正畸科,上海交通大学口腔医学院,国家口腔医学中心,国家口腔疾病临床医学研究中心,上海市口腔医学重点实验室,上海市口腔医学研究所,上海200011
出 处:《上海口腔医学》2023年第5期491-496,共6页Shanghai Journal of Stomatology
基 金:国家自然科学基金(81801006);上海交通大学医学院附属第九人民医院基础研究项目(JYZZ136);上海交通大学“交大之星”计划医工交叉研究基金(YG2022QN052)。
摘 要:目的:利用口内光学扫描技术评价导板种植精度并探讨其影响因素。方法:选择符合纳入标准的牙列缺损患者27例,进行回顾性研究。利用3Shape Implant Studio软件设计种植方案并生成相应的数字化导板,临床进行引导种植手术。使用3Shape TRIOS口内扫描仪获取术后牙列数字化模型,在Geomagic软件中逆向构建植体位置,结合术前方案中设计位点,评价种植体偏移情况。采用SAS 9.4软件包进行数据分析。结果:以光学扫描方法得到数字化导板精度为植入点偏差(1.182±0.609)mm,根尖点偏差(1.658±0.741)mm,角度偏差(5.712±3.347)°。种植导板的距离偏移可能受工作象限、缺牙位点、引导程度、黏膜辅助支持、种植体尺寸等临床因素影响,而角度偏移主要受引导程度和缺牙数量影响。结论:数字化导板的临床效果受到诸多因素影响,提高数字化导板种植精度需要更多研究数据支持。PURPOSE:To evaluate the accuracy of static guided implant placement with intraoral scanning technology and to analyze the influencing factors of guided surgery.METHODS:Totally 27 cases were included in this retrospective study.The implant designs were made in 3Shape Implant Studio and then guided implant surgeries were performed with CAD-CAM templates.Postoperative implant positions were detected with an intraoral scanner(3Shape TRIOS)and deviation of implantation was evaluated using established CAD/CAM based evaluation method.SAS 9.4 software package was used for data analysis.RESULTS:The mean deviation of entrance point and apical point was(1.182±0.609)mm and(1.658±0.741)mm,respectively.Angular deviation was(5.712±3.347)°.Implant quadrant,location of the implant site,guidance degree,supporting type and implant size influenced direction deviation,while angular deviation was mainly affected by guidance degree and number of missing teeth.CONCLUSIONS:Accuracy of static guided implant placement can be influenced by many factors.More research is needed to improve the accuracy of static guided implantation.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.33