Biometric and ICL-related risk factors associated to sub-optimal vaults in eyes implanted with implantable collamer lenses  

在线阅读下载全文

作  者:Santiago Cerpa Manito Angel Sánchez Trancón Oscar Torrado Sierra António Manuel Baptista Pedro Miguel Serra 

机构地区:[1]Research and Development Department,Ophthalmology Clinic Vista Sánchez Trancón,Building Tecnolaser,Room 14 Calle La Violeta,06005 Badajoz,Spain [2]Center of Physics,University of Minho,Braga,Portugal [3]Optics and Optometry Department,Instituto Superior de Educação e Ciências,Lisbon,Portugal

出  处:《Eye and Vision》2023年第5期1-10,共10页眼视光学杂志(英文)

摘  要:Background To identify biometric and implantable collamer lens(ICL)-related risk factors associated with sub-optimal postoperative vault in eyes implanted with phakic ICL.Methods This study reports a retrospective case series of the first operated eye in 360 patients implanted with myopic spherical or toric ICL.Preoperatively,white-to-white(WTW),central keratometry(Kc)and central corneal thickness(CCT)were measured using the Pentacam.Anterior-segment optical coherence tomography(AS-OCT,Visante)was applied preoperatively for measuring the horizontal anterior-chamber angle-to-angle distance(ATA),internal anterior chamber depth(ACD),crystalline lens rise(CLR),anterior-chamber angle(ACA)and postoperatively the vault.Eyes were divided into three vault groups:low(LVG:≤250μm),optimal(OVG:>250 and<1000μm)and high(HVG:≥1000μm).Multinomial logistic regression(MLR)was used to find the sub-optimal vault predictors.Results MLR showed that CLR,ICL size minus the ATA(ICL size-ATA),age,ICL spherical equivalent(ICLSE)and ICL size as contributing factors for sub-optimal vaults(pseudo-R2=0.40).Increased CLR(OR:1.01,CI:1.00–1.01)and less myopic ICLSE(OR:1.22,CI:1.07–1.40)were risk factors for low vaults.Larger ICL size-ATA(OR:41.29,CI:10.57–161.22)and the 13.7 mm ICL(OR:7.08,CI:3.16–15.89)were risk factors for high vaults,whereas less myopic ICLSE(OR:0.85,CI:0.76–0.95)and older age(OR:0.92,CI:0.88–0.98)were protective factors.Conclusion High CLR and low ICLSE were the major risk factors in eyes presenting low vaults.In the opposite direction,ICL size-ATA was the major contributor for high vaults.This relationship was more critical in higher myopic ICLSE,younger eyes and when 13.7 mm ICL were used.The findings show that factors influencing the vault have differentiated weight of influence depending on the type of vault(low,optimal or high).

关 键 词:Implantable collamer lens Refractive surgery VAULT Risk factors 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象