光伏并网逆变器分数阶滑模二自由度内模控制  

Fractious-order Sliding Module Two-degree-of-freedom Internal Module Control for Grid-connected Photovoltaic Inverter

在线阅读下载全文

作  者:张冬冬 葛孟超 李保宗 于培培 李达 逯哲 ZHANG Dongdong;GE Mengchao;LI Baozong;YU Peipei;LI Da;LU Zhe

机构地区:[1]中铁电气工业有限公司

出  处:《电气化铁道》2023年第6期67-71,共5页Electric Railway

摘  要:为提高光伏并网逆变器的动态品质和鲁棒性能,削减传统滑模控制中存在的系统抖振,改善一自由度内模控制无法兼顾系统跟随性和抗干扰性的局限性,通过引入分数阶微积分算子和二自由度内模控制算法,提出一种光伏并网逆变器分数阶滑模二自由度内模控制方法。经仿真测试结果表明,相较于传统滑模一自由度内模控制算法,该控制方法具有较好的并网跟随性,在网压波动时可有效削减系统抖振,改善系统抗干扰能力,提升系统的鲁棒性。In order to heighten the dynamic quality and robust performance of grid-connected photovoltaic inverter,reduce the limitations of taking into consideration of following performance and anti-interference inside the one-degree-of-freedom internal module control,by introducing fractious-order integrate differential operator and two-degree-of-freedom internal module control algorithm,a fractious-order integral differential operator method for grid-connected photovoltaic inverter is put forward.The simulation and test results show that the control method has good following performance of grid-connection,compared with the traditional sliding module one-degree-of-freedom internal module control method.It is able to effectively reduce the system jittering when the grid voltage is fluctuating,improve the system anti-interference capability and improve the system robustness.

关 键 词:逆变器 分数阶滑模 二自由度内模 鲁棒稳定 

分 类 号:U223.5[交通运输工程—道路与铁道工程]

 