Deep learning-based magnetic resonance imaging reconstruction for improving the image quality of reduced-field-of-view diffusionweighted imaging of the pancreas  被引量:1

在线阅读下载全文

作  者:Yukihisa Takayama Keisuke Sato Shinji Tanaka Ryo Murayama Nahoko Goto Kengo Yoshimitsu 

机构地区:[1]Department of Radiology,Faculty of Medicine,Fukuoka University,Fukuoka 8140180,Japan

出  处:《World Journal of Radiology》2023年第12期338-349,共12页世界放射学杂志(英文版)(电子版)

摘  要:BACKGROUND It has been reported that deep learning-based reconstruction(DLR)can reduce image noise and artifacts,thereby improving the signal-to-noise ratio and image sharpness.However,no previous studies have evaluated the efficacy of DLR in improving image quality in reduced-field-of-view(reduced-FOV)diffusionweighted imaging(DWI)[field-of-view optimized and constrained undistorted single-shot(FOCUS)]of the pancreas.We hypothesized that a combination of these techniques would improve DWI image quality without prolonging the scan time but would influence the apparent diffusion coefficient calculation.AIM To evaluate the efficacy of DLR for image quality improvement of FOCUS of the pancreas.METHODS This was a retrospective study evaluated 37 patients with pancreatic cystic lesions who underwent magnetic resonance imaging between August 2021 and October 2021.We evaluated three types of FOCUS examinations:FOCUS with DLR(FOCUS-DLR+),FOCUS without DLR(FOCUS-DLR−),and conventional FOCUS(FOCUS-conv).The three types of FOCUS and their apparent diffusion coefficient(ADC)maps were compared qualitatively and quantitatively.RESULTS FOCUS-DLR+(3.62,average score of two radiologists)showed significantly better qualitative scores for image noise than FOCUS-DLR−(2.62)and FOCUS-conv(2.88)(P<0.05).Furthermore,FOCUS-DLR+showed the highest contrast ratio and 600 s/mm^(2)(0.72±0.08 and 0.68±0.08)and FOCUS-DLR−showed the highest CR between cystic lesions and the pancreatic parenchyma for the b-values of 0 and 600 s/mm2(0.62±0.21 and 0.62±0.21)(P<0.05),respectively.FOCUS-DLR+provided significantly higher ADCs of the pancreas and lesion(1.44±0.24 and 3.00±0.66)compared to FOCUS-DLR−(1.39±0.22 and 2.86±0.61)and significantly lower ADCs compared to FOCUS-conv(1.84±0.45 and 3.32±0.70)(P<0.05),respectively.CONCLUSION This study evaluated the efficacy of DLR for image quality improvement in reduced-FOV DWI of the pancreas.DLR can significantly denoise images without prolonging the scan time or decreasing the spatial resolu

关 键 词:Deep learning-based reconstruction Magnetic resonance imaging Reduced field-of-view Diffusion-weighted imaging PANCREAS 

分 类 号:R576[医药卫生—消化系统]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象