检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Muteb Alanazi Patrick Caroline Amane Alshamrani Maria Liu
机构地区:[1]Optometry Department,College of Applied Medical Sciences,King Saud University,Riyadh 14813,Saudi Arabia [2]College of Optometry,Pacific University,Forest Grove,Oregon 97116-1756,United States [3]Optometry School,University of California at Berkeley,California 94720,United States
出 处:《International Journal of Ophthalmology(English edition)》2024年第2期247-256,共10页国际眼科杂志(英文版)
基 金:the Deputyship for Research and Innovation,Ministry of Education in Saudi Arabia for funding this research work through the project(No.IFKSUOR3-433-1)。
摘 要:AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments.
关 键 词:CHOROID gas-permeable contact lens retinal defocus axial length MYOPIA
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.200