端钩型钢纤维混凝土简支梁受弯承载力试验  被引量:1

Experiment on Flexural Bearing Capacity of Hooked-end Steel Fiber Reinforced Concrete Simply-supported Beam

在线阅读下载全文

作  者:武斌[1] 武赛琴 武浩兵 张媛媛 张强[1] WU Bin;WU Sai-qin;WU Hao-bing;ZHANG Yuan-yaun;ZHANG Qiang(School of Electric Power,Civil Engineering and Architecture,Shanxi University,Taiyuan 030031,China;Department of Architecture and Environmental Engineering,Taiyuan University,Taiyuan 030032,China;China Special Equipment Testing and Research Institute,Beijing 100031,China)

机构地区:[1]山西大学电力与建筑学院,太原030031 [2]太原学院建筑与环境工程系,太原030032 [3]中国特种设备检测研究院,北京100031

出  处:《科学技术与工程》2024年第4期1597-1608,共12页Science Technology and Engineering

基  金:国家自然科学基金(11802166);山西省重点研发计划(20191D211121);山西省基础研究计划(20210302124116)。

摘  要:为改善普通钢筋混凝土梁自重大、易开裂、承载力低等缺点,在混凝土中常加入钢纤维,端钩型钢纤维,作为常见的一种高性能钢纤维得到广泛关注,中外学者针对端钩型钢纤维混凝土的基本力学性能开展了较多研究,而对端钩型钢纤维混凝土受弯构件的正截面受力性能有待深入研究。为研究端钩型钢纤维混凝土简支梁受弯性能,制作4根端钩型钢纤维混凝土梁及1根普通混凝土梁,对其进行受弯性能试验,根据试验得到的破坏形态、承载力、荷载-挠度曲线、荷载-应变曲线,分析端钩型钢纤维体积掺量对试件受弯承载力及破坏形态的影响。结果表明:端钩型钢纤维混凝土简支梁与一般混凝土简支梁受弯过程类似,均经历了弹性、开裂、带裂缝工作、破坏4个阶段;端钩型钢纤维混凝土简支梁与一般混凝土简支梁受弯过程均基本符合“平截面假定”;端钩型钢纤维限制了裂缝的产生和发展,使得纤维混凝土梁变形能力增强;与一般混凝土梁相比,端钩型钢纤维混凝土梁抗裂性及极限承载力得到提高,且构件承载力与钢纤维体积掺量基本呈现正相关;基于试验数据,对现行规范中开裂弯矩及极限承载力计算公式进行优化,开裂弯矩方面考虑对截面抵抗矩塑性影响系数进行修正,极限承载力方面引入纤维混凝土正截面承载力影响系数ζ,经修正计算值可较好吻合试验值。In order to improve the disadvantages of ordinary reinforced concrete beams,such as large deadweight,easy cracking and low bearing capacity,steel fiber is often added to concrete.As a common high-performance steel fiber,hooked-end steel fiber was widely concerned.Scholars at home and abroad carry out a lot of research on the basic mechanical properties of hooked-end steel fiber reinforced concrete,but the bending members of hooked-end steel fiber reinforced concrete needs further study.In order to study the flexural behavior of hooked-end steel fiber concrete simply-supported beam,four hooked-end steel fiber reinforced concrete beams and one reinforced concrete beam were made,and their flexural behavior tests were carried out.According to the failure form,bearing capacity,load-deflection curve and load-strain curve were obtained from the tests,the influence of the volume content of the hooked-end steel fiber on the flexural bearing capacity and failure form of the specimen was analyzed.The results show that the bending process of hooked-end steel fiber reinforced concrete simply-supported beams is similar to that of ordinary concrete beams,and they have experienced four stages:elasticity,cracking,working with cracks,and failure.The bending process of hooked-end steel fiber reinforced concrete simply-supported beams and ordinary concrete simply-supported beams basically conforms to the“plane section assumption”.Hooked-end steel fiber restricts the generation and development of cracks,and enhances the deformation ability of steel fiber reinforced concrete beams.Compared with ordinary concrete beams,the crack resistance and ultimate bearing capacity of hooked-end steel fiber reinforced concrete beams are improved,and the bearing capacity of members is basically positively correlated with the volume content of steel fiber.Based on the test data,the calculation formula of cracking moment and ultimate bearing capacity in the current code is optimized.In the aspect of cracking moment,it is considered to modify the p

关 键 词:端钩型钢纤维 钢纤维混凝土简支梁 受弯性能 开裂弯矩 极限承载力 

分 类 号:TU375[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象