透平级小翼-凹槽叶顶冷却传热性能研究  被引量:1

Investigations Into Film Cooling and Heat Transfer Performance on Winglet-Squealer Tips in a Turbine Stage

在线阅读下载全文

作  者:吴琛琦 秦正 何坤[1] 晏鑫[1] WU Chenqi;QIN Zheng;HE Kun;YAN Xin(School of Energy&Power Engineering,Xi’an Jiaotong University,Xi’an 710049,China)

机构地区:[1]西安交通大学能源与动力工程学院,陕西西安710049

出  处:《工程热物理学报》2024年第2期401-409,共9页Journal of Engineering Thermophysics

基  金:国家自然科学基金(No.52076165)。

摘  要:采用数值方法研究了发动机工况下含内冷通道的透平级小翼-凹槽叶顶的冷却传热性能,分析了叶顶型式、吹风比对叶顶传热系数和气膜冷却效率分布的影响。结果表明:带压力侧小翼凹槽叶顶可有效消除叶顶刮削涡,改善凹槽底部冷气覆盖的均匀性;相对于传统凹槽叶顶,带压力侧小翼凹槽叶顶的面积平均传热系数减小11.11%、气膜冷却效率增大4.54%。吹风比从1增大到2时,带压力侧小翼凹槽叶顶面积平均传热系数减小48.96%、气膜冷却效率增大154.01%。Film cooling and heat transfer performance on the winglet-squealer tip of a turbine stage with internal cooling channels were numerically investigated under engine condition.The effects of tip geometry and blowing ratio on the heat transfer coefficient and film cooling effectiveness distributions on the squealer tip were analyzed.The results showed that the existence of pressure-side winglet is able to eliminate the scrapping vortex in tip gap,thus improving the uniformity of coolant coverage on the squealer cavity floor.Compared to the conventional squealer tip,the area-averaged heat transfer coefficient is reduced by 11.11%and the area-averaged film cooling effectiveness is increased by 4.54%for the pressure side winglet-squealer tip.As the blowing ratio increases from 1.0 to 2.0,the area-averaged heat transfer coefficient on the winglet-squealer tip is reduced by 48.96%,and the area-averaged film cooling effectiveness on the winglet-squealer tip is improved by 154.01%.

关 键 词:凹槽叶顶 小翼 传热 气膜冷却 吹风比 

分 类 号:TK474.7[动力工程及工程热物理—动力机械及工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象