作 者:张建文 李博[1] 林冠宇[1] 顾国超[1] 李寒霜 王晓旭[1] 胡登辉 Zhang Jianwen;Li Bo;Lin Guanyu;Gu Guochao;Li Hanshuang;Wang Xiaoxu;Hu Denghui(Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,Jilin,China;University of Chinese Academy of Sciences,Beijing 100049,China;Innovation Academy for Microsatellites,Chinese Academy of Sciences,Shanghai 201200,China)
机构地区:[1]中国科学院长春光学精密机械与物理研究所,吉林长春130033 [2]中国科学院大学,北京100049 [3]中国科学院微小卫星创新研究院,上海201200
出 处:《激光与光电子学进展》2024年第4期199-205,共7页Laser & Optoelectronics Progress
基 金:国家自然科学基金(62005268);黑土地保护与利用科技创新工程专项(XDA28050102)。
摘 要:为了实现差分吸收激光雷达对臭氧浓度和气溶胶的同时探测,对常见的三通道分光光谱仪进行改进优化。确定光谱仪初始结构后,使用光栅方程对四通道的摆放位置进行计算分析。使用球面镜和全息光栅,通过添加距离约束,将四个光谱通道控制在合理的机械结构范围内,最终设计了一款四通道分光、低F数的光谱仪系统。该系统使用圆阵列转线列光纤,提高了接收系统对大气回波信号的接收强度,实现了对266,289,316,532 nm回波信号强度的精确探测。设计结果表明,光谱仪系统可连接0.12数值孔径的线列光纤,在266,289,316 nm光谱分辨力优于0.5 nm,在532 nm处光谱分辨力优于1 nm,满足激光雷达探测光谱分辨率的要求。分析了光谱仪出射狭缝的曲率半径和圆心位置。该设计可实现激光雷达对气溶胶和臭氧的同时探测,简化了系统结构。In this study,the common three-channel spectrometer was improved and optimized to realize the simultaneous detection of ozone and aerosol concentration using differential absorption lidar.First,the initial structure of the spectrometer is determined,followed by the calculation and analysis of the position of the four channels using the raster equation.Then,the four spectral channels are controlled within a reasonable mechanical structure range by adding distance constraints using a spherical mirror and a holographic grating.Finally,a four-channel and low F number spectrometer system is designed.The system uses circular array to linear fiber to improve the reception intensity of the receiving system for atmospheric echo signals and realizes accurate detection for 266,289,316,and 532 nm echo signal strength.The results show that the proposed spectrometer system can be connected to a linear fiber with a 0.12 NA.The obtained spectral resolution is better than 0.5 nm and 1 nm at 266,289,316 and 532 nm,respectively,thus,meeting the spectral resolution requirements of lidar detection.Moreover,the spectrometer’s radius of curvature of the exit slit and the center position of the circle are analyzed.Our findings show that the proposed design can realize the simultaneous detection of aerosol and ozone by lidar and can also simplify the system structure.
分 类 号:TN958.98[电子电信—信号与信息处理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.26