检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李牧[1,2] 骆宇 柯熙政[1,2] LI Mu;LUO Yu;KE Xizheng(Faculty of Automation and Information Engineering,Xi’an University of Technology,Xi’an Shaanxi 710048,China;Xi’an Key Laboratory of Wireless Optical Communication and Network Research(Xi’an University of Technology),Xi'an Shaanxi 710048,China)
机构地区:[1]西安理工大学自动化与信息工程学院,西安710048 [2]西安市无线光通信与网络研究重点实验室(西安理工大学),西安710048
出 处:《计算机应用》2024年第6期1978-1986,共9页journal of Computer Applications
基 金:西安市科技计划项目(2020KJRC0083)。
摘 要:针对现有雷达非接触生命体征检测精度低、实时性差等问题,提出一种基于调频连续波(FMCW)雷达的人体生命体征检测算法。首先,通过毫米波雷达获取生命体征信号;其次,利用改进的经验小波变换(EWT)算法,实现生命体征信号的自适应分解和重构,通过引入麻雀搜索算法(SSA)和模糊熵(FE)寻找频谱分割线的最优值;最后,通过改进频率插值的估计算法计算心率和呼吸频率。通过与医用重症监护仪进行对比实验验证所提算法的优越性和鲁棒性。实验结果表明,所提算法相较于小波变换(WT)算法、CEEMD(Complementary Ensemble Empirical Mode Decomposition)算法和VMD(Variational Mode Decomposition)算法,均方误差(MSE)分别减小了77.65、27.25和21.05,平均绝对百分比(MAPE)分别减小了7.33、4.33和3.42个百分点,实时性分别提高了0.72 s, 16.74 s和1.87 s。同时,利用所提算法也实现了对心率变异性(HRV)的检测。For problems such as low accuracy and poor real-time detection of existing radar non-contact vital signs detection,a human vital signs detection algorithm based on Frequency Modulated Continuous Wave(FMCW)radar was proposed.Firstly,the vital signs signal was obtained through the millimeter wave radar.Then,the adaptive decomposition and reconstruction of the vital signs signal were achieved using the improved Empirical Wavelet Transformation(EWT)algorithm.The best value of the spectrum division line was found by introducing Sparrow Search Algorithm(SSA)and Fuzzy Entropy(FE).Finally,the heart rate and respiratory rate were calculated using the estimation algorithm with improved frequency interpolation.The superiority and robustness of the proposed algorithm were verified through comparative experiments with a medical critical care monitor.The experimental results showed that compared with Wavelet Transform(WT)algorithm,Complementary Ensemble Empirical Mode Decomposition(CEEMD)algorithm and Variational Mode Decomposition(VMD)algorithm,the Mean Square Error(MSE)was reduced by 77.65,27.25 and 21.05,the Mean Absolute Percentage(MAPE)was reduced by 7.33,4.33 and 3.42 percentage points,and the real-time performance was improved by 0.72 s,16.74 s and 1.87 s.At the same time,the proposed algorithm also achieves the detection of Heart Rate Variability(HRV).
关 键 词:毫米波雷达 经验小波变换 生命体征 心率变异性 麻雀搜索算法
分 类 号:TN959.1[电子电信—信号与信息处理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.149.239.180