检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Hui Tang Barry Munkasy Li Li
机构地区:[1]Department of Health Sciences and Kinesiology,Georgia Southern University,Statesboro,GA 30458,USA [2]Department of Kinesiology and Health Education,University of Texas at Austin,Austin,TX 78712,USA
出 处:《Journal of Sport and Health Science》2024年第4期569-578,共10页运动与健康科学(英文)
摘 要:Background:The development of computer vision technology has enabled the use of markerless movement tracking for biomechanical analysis.Recent research has reported the feasibility of markerless systems in motion analysis but has yet to fully explore their utility for capturing faster movements,such as running.Applied studies using markerless systems in clinical and sports settings are still lacking.Thus,the present study compared running biomechanics estimated by marker-based and markerless systems.Given running speed not only affects sports performance but is also associated with clinical injury prevention,diagnosis,and rehabilitation,we aimed to investigate the effects of speed on the comparison of estimated lower extremity joint moments and powers between markerless and marker-based technologies during treadmill running as a concurrent validating study.Methods:Kinematic data from marker-based/markerless technologies were collected,along with ground reaction force data,from 16 young adults running on an instrumented treadmill at 3 speeds:2.24 m/s,2.91 m/s,and 3.58 m/s(5.0 miles/h,6.5 miles/h,and 8.0 miles/h).Sagittal plane moments and powers of the hip,knee,and ankle were calculated by inverse dynamic methods.Time series analysis and statistical parametric mapping were used to determine system differences.Results:Compared to the marker-based system,the markerless system estimated increased lower extremity joint kinetics with faster speed during the swing phase in most cases.Conclusion:Despite the promising application of markerless technology in clinical settings,systematic markerless overestimation requires focused attention.Based on segment pose estimations,the centers of mass estimated by markerless technologies were farther away from the relevant distal joint centers,which led to greater joint moments and powers estimates by markerless vs.marker-based systems.The differences were amplified by running speed.
关 键 词:BIOMECHANICS Motion capture GAIT Statistical parametric mapping
分 类 号:G804.6[文化科学—运动人体科学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.104