Effects of lighting conditions and accommodation on the three-dimensional position of Visian implantable collamer lens  

在线阅读下载全文

作  者:Lingling Niu Zhe Zhang Huamao Miao Jing Zhao Xiaoying Wang Ji C.He Xingtao Zhou 

机构地区:[1]Department of Ophthalmology and Optometry,Eye&ENT Hospital,Fudan University,Shanghai,China [2]NHC Key Laboratory of Myopia(Fudan University),Shanghai,China [3]Key Laboratory of Myopia,Chinese Academy of Medical Sciences,Shanghai,China [4]Shanghai Research Center of Ophthalmology and Optometry,Shanghai,China [5]New England College of Optometry,MA,Boston,USA

出  处:《Eye and Vision》2024年第3期31-40,共10页眼视光学杂志(英文)

基  金:supported by the National Natural Science Foundation of China(Grant No.81770955);Research Project Grant of Shanghai Municipal Health Commission(Grant No.202040285);Project of Shanghai Science and Technology(Grant No.20410710100);Joint research project of new frontier technology in municipal hospitals(Grant No.SHDC12018103);Clinical Research Plan of SHDC(Grant No.SHDC2020CR1043B);Project of Shanghai Xuhui District Science and Technology(Grant No.2020-015).

摘  要:Background To investigate the effects of lighting conditions and accommodation on the three-dimensional position of Visian implantable collamer lens(ICL V4c).Methods This observational study recruited 62 eyes of 31 myopia patients underwent ICL V4c implantation.Anterior segment optical coherence tomography(AS-OCT)assessed the anterior chamber depth(ACD),ACD-ICL(distance from the corneal endothelium to anterior surface of the ICL V4c),vault(distance between the posterior ICL V4c surface and anterior crystalline lens surface),and crystalline lens tilt under various lighting conditions and accommodation relative to the corneal topographic axis at one year after ICL V4c implantation.Baseline was defined as the scotopic condition,which was also the non-accommodative stimulus condition.The ICL V4c tilt was analyzed using MATLAB.The significance level was set at P<0.05.Results The ACD-ICL values were similar under various lighting conditions(P=0.978)but decreased during accommodation(P<0.001).The vault was significantly smaller under mesopic and photopic conditions than the baseline(P=0.044 and P<0.001,respectively)but remained unchanged during accommodation(P=0.058).The inferotemporal proportion of ICL V4c(88.7%,55 eyes)and crystalline lens(74.2%,46 eyes)tilts were not significantly different(P=0.063).Crystalline lens under various lighting conditions and accommodation exhibited similar tilts.The vertical tilt of ICL V4c was significantly larger under photopic conditions than the baseline(P=0.038).The horizontal and total tilts were significantly decreased during accommodation(P=0.043 and 0.013,respectively).Conclusions The axial position of ICL V4c in the anterior chamber was stable under various lighting conditions.Lighting conditions and accommodation may influence vertical,horizontal and total tilts of ICL V4c.

关 键 词:Implantable collamer lens Anterior segment optical coherence tomography MYOPIA TILT 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象