Superior rectus/levator complex in acquired anophthalmic socket repaired with spheric implant—a computed tomography scan and topographic study  

在线阅读下载全文

作  者:Shaikha Al Eid Hamad M AlSulaiman Sahar M Elkhamary Osama Al Sheikh Alicia Ferrero-Galindo Rajiv Kandekhar Silvana A Schellini 

机构地区:[1]Oculoplastic Division,King Khaled Eye Specialist Hospital,Riyadh 11462,Saudi Arabia [2]Radiology Division,King Khaled Eye Specialist Hospital,Riyadh 11462,Saudi Arabia [3]Department of Diagnostic Radiology,Mansoura Faculty of Medicine,Mansoura 35511,Egypt [4]University Hospital Rio Hortega,Valladolid 47012,Spain [5]Research Department,King Khaled Eye Specialist Hospital,Riyadh 11462,Saudi Arabia [6]Ophthalmology Department,Medical School,State University of Sao Paulo,Botucatu 18618-687,Brazil

出  处:《International Journal of Ophthalmology(English edition)》2024年第8期1483-1488,共6页国际眼科杂志(英文版)

摘  要:AIM:To determine whether the levator palpebrae superioris(LPS)/superior rectus(SR)muscle complex,can influence the position of the upper lid and fornix in acquired anophthalmic sockets.METHODS:This comparative non-randomized and non-interventional study included retrospective data of 21 patients with unilateral acquired anophthalmic sockets repaired with spheric implants.High-resolution computed tomography(CT)measurements of the LPM/SR muscle complex and clinical topographic position of the upper lid,superior and inferior fornix depth in primary gaze position were evaluated.Demographic data were presented as frequency and percentage proportions and quantitative variables comparing the socket measurements with the normal contralateral orbit was statistically analyzed using non-parametric tests considering P<0.05.RESULTS:The anophthalmic orbits had a significantly shorter LPS length(P=0.01)and significantly thicker SR(P=0.02)than the normal orbit.Lagophthalmos was present in anophthalmic sockets but not in normal orbits(P=0.002),while levator function was normal in both(P>0.05,all comparisons).The superior fornix depth was similar in the anophthalmic socket and the contralateral normal orbit(P=0.192)as well the inferior fornix depth(P=0.351).CONCLUSION:Acquired anophthalmic sockets repaired with spheric implants have shorter LPS,thicker SR,and more lagophthalmos than normal orbits.The relationship of the LPS and SR with other orbital structures,associated with passive or active forces acting in the final position of the lids and external ocular prosthesis should be further investigated.

关 键 词:anophthalmic socket spheric implant levator palpebrae superioris superior rectus lagophthalmos fornix depth 

分 类 号:R779.6[医药卫生—眼科]

 