检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈清华[1,2,3,4] 许曾生 王小润 江丙友 唐明云[3] 胡祖祥[3] 邱进伟[3] 周亮[3] CHEN Qinghua;XU Zengsheng;WANG Xiaorun;JIANG Bingyou;TANG Mingyun;HU Zuxiang;QIU Jinwei;ZHOU Liang(Anhui Provincial Key Laboratory of Mining Intelligent Equipment and Technology,Anhui University of Science and Technology,Huainan232001,China;Institute of Environmental Friendly Materials and Occupational Health,Anhui University of Science and Technology,Wuhu241003,China;Key Laboratory of Industrial Dust Prevention and Control,Occupational Safety and Health,Ministry of Education,Anhui University of Science and Technology,Huainan 232001,China;School of Mechanical Engineering,Anhui University of Science and Technology,Huainan 232001,China)
机构地区:[1]安徽理工大学矿山智能装备与技术安徽省重点实验室,安徽淮南232001 [2]安徽理工大学环境友好材料与职业健康研究院(芜湖),安徽芜湖241003 [3]安徽理工大学工业粉尘防控与职业安全健康教育部重点实验室,安徽淮南232001 [4]安徽理工大学机械工程学院,安徽淮南232001
出 处:《煤炭学报》2024年第7期2997-3006,共10页Journal of China Coal Society
基 金:国家重点研发计划资助项目(2022YFC2503200,2022YFC2503201);安徽理工大学芜湖研究院研发专项资助项目(ALW2021YF12)。
摘 要:传统滤膜称重法操作过程繁琐、检测周期长,且自动化程度低,虽精度高但无法满足粉尘质量浓度实时检测需求。设计了粉尘质量浓度自动检测装置,通过建立温湿度补偿模型,替代手工称重法中采样后滤膜烘干的步骤,进一步缩减粉尘质量浓度检测时间以及粉尘质量浓度检测装置体积。搭建试验样机并调试实验,结果表明,煤矿井下常用的CCZ-20A型粉尘采样器与本装置检测得到的粉尘质量折算浓度经过计算其标准偏差在5%以内,一元线性回归拟合分析下的实验数据拟合相关性较好。为进一步提升装置的检测精度,研究基于傅里叶级数、线性拟合以及周期拟合相结合的误差补偿方法,设计出装置浓度计算流程并代入原始数据中,将该装置检测浓度误差由原始的(-7.20%,-1.26%)集中至(-3.64%,3.65%)。引入装置浓度计算流程后进行多次对比实验,实验结果显示装置浓度检测误差均在此区间内,验证了装置浓度计算流程的可靠性。该装置缩短了粉尘质量浓度检测所需时间,同时检测误差控制在合理的范围内,进而为滤膜称重法在粉尘质量浓度在线监测方面的研究提供一定的参考。The traditional filter weighing method has a cumbersome operation process,a long detection cycle,and a low degree of automation.Although it has high accuracy,it cannot meet the needs of real-time detection of dust concentration.An automatic dust mass concentration detection device was designed,and the temperature and humidity compensation model was established to replace the steps of filter membrane drying after sampling in the manual weighing method,so as to further reduce the dust concentration detection time and the volume of the dust concentration detection device.The pro-totype device was built and the experiment was conducted.The test results showed that the standard deviation of the CCZ-20A dust sampler commonly used in coal mines and the converted concentration of dust detected by this device was with-in 5%,and the fitting correlation of the experimental data under the univariate linear regression fitting analysis was good.In order to further improve the detection accuracy of the device,an error compensation method based on the combination of Fourier series,linear fitting and periodic fitting was studied,and the concentration calculation process of the device was established and brought into the original data,and the detection concentration error of the device was concentrated from the original(−7.20%,−1.26%)to(−3.64%,3.65%).After the introduction of the device concentration calculation process,several comparative experiments were carried out,and the experimental results showed that the detection errors of the device concentration were within this range,which verified the reliability of the device concentration calculation process.The device shortens the time required for dust concentration detection,and at the same time controls the detection error within a reasonable range,which provides a reference for the research of filter membrane weighing method in the online monitoring of dust concentration.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7