检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:尹凯 龚琳 段天英[1] 侯斌 戴饶棋 刘勇[1] 胡加永 Yin Kai;Gong Lin;Duan Tianying;Hou Bin;Dai Raoqi;Liu Yong;Hu Jiayong(Department of Nuclear Engineering and Design,China Institute of Atomic Energy,Beijing,102413,China)
机构地区:[1]中国原子能科学研究院核工程设计研究所,北京102413
出 处:《核动力工程》2024年第4期155-161,共7页Nuclear Power Engineering
摘 要:基于RELAP/GSE联合MATLAB/Simulink平台,针对小型钠冷快堆耦合斯特林热电转换模块的方案开展仿真建模,以研究某小型钠冷快堆核电源系统的负荷跟踪运行能力及运行模式。针对负荷阶跃且无控制系统介入的极端情况,分层次考验核电源各回路系统的负荷跟踪能力,同时提出适应负荷跟踪模式下的控制方案并进行验证。仿真结果表明,该电源系统可承受±10%的负荷阶跃变化,具有较强的配合电网调峰的负荷跟踪能力。同时,本研究提出了该电源系统负荷跟踪运行模式的两套协调控制方案,通过仿真分析和比选给出了适用于小型钠冷快堆电源负荷跟踪运行模式的协调控制方案。Based on the platform of RELAP/GSE combined with MATLAB/Simulink,a simulation model is established for the scheme of coupling Stirling thermoelectric conversion module in small sodium-cooled fast reactors,so as to study the load following operation capability and operation mode of the nuclear power supply system of a small sodium-cooled fast reactor.In the extreme case of load step and no control system intervention,the load-following capability of each loop system of nuclear power supply is tested in a hierarchical manner,and a control scheme suitable for load-following mode is proposed and verified.The simulation results show that the power supply system has the ability to withstand±10%load step changes and has strong load-following capability to cooperate with grid peak shaving.At the same time,this research proposes two coordinated control schemes for the load-following operation mode of the power supply system,and provides a coordinated control scheme suitable for the load-following operation mode of the small sodium reactor power supply through simulation analysis and comparison.
关 键 词:小型钠冷快堆 斯特林 负荷跟踪 控制方案 SIMULINK
分 类 号:TL425[核科学技术—核技术及应用]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.117.135.125